- E1 — On GE Profile DPVH890 dryers (technical service manual): Interface EEPROM fault - the user interface board is reading or writing its memory…
- E10 — On GE Profile DPVH890 dryers (technical service manual): Blower Motor fault - the blower motor is not rotating properly.
- E101 — On GE Profile DPVH890 dryers (technical service manual): Power EEPROM fault - the power board is reading or writing its memory improperly…
- E11 — On GE Profile DPVH890 dryers (technical service manual): Blocked Airflow - check the ventilation system.
- E12 — On GE Profile DPVH890 dryers (technical service manual): Drum Motor fault - the motor is not rotating properly, or the centrifugal switch…
- E16 — On GE Profile DPVH890 dryers (technical service manual): LIN Communication Failure - a problem with communication between the machine…
- E17 — On GE Profile DPVH890 dryers (technical service manual): VFD Communication Error - a problem with the serial communication interface…
- E18 — On GE Profile DPVH890 dryers (technical service manual): Stuck Button - one or more keys are stuck.
- E2 — On GE Profile DPVH890 dryers (technical service manual): Inlet Short - the inlet thermistor is shorted; check and replace if necessary.
- E3 — On GE Profile DPVH890 dryers (technical service manual): Outlet Short - the outlet thermistor is shorted; check and replace if necessary.
- E4 — On GE Profile DPVH890 dryers (technical service manual): Inlet Open - the inlet thermistor circuit is open; check and replace if necessary.
- E5 — On GE Profile DPVH890 dryers (technical service manual): Outlet Open - the outlet thermistor circuit is open; check and replace if…
- E61 — On GE Profile DPVH890 dryers (technical service manual): Check Electrical Connection - the input voltage is too high; check the power…
- E81 — On GE Profile DPVH890 dryers (technical service manual): Power Model fault - no model select connector was detected; check the model…