GE Dryer Profile DPVH890 Series E18 Error Code
What the E18 code means
On GE Profile DPVH890 dryers (technical service manual): Stuck Button - one or more keys are stuck.
Likely causes
- A key physically stuck down
- Something pressing against the control panel
- Residue or moisture under a key
How to fix it — step by step
- Press and release every key on the panel to free the stuck one
- Wipe the panel clean and remove anything leaning on it
- Unplug for a few minutes, then restore power
- If E18 returns immediately, the panel/UI needs service
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the user interface board.
Parts that commonly fix the E18 code
- user interface board - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official GE manual is on GE's support site — you'll need your model number.
Find your model number inside the door on the frame. It's the key to the right manual pages and the right parts.