Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) UA Error Code

What the UA code means

UA is the indoor-outdoor combination fault. Daikin's documents phrase it three ways that all describe the same thing: the service manual detects it as an unspecified voltage between the units when pair-type and multi-type equipment are interconnected (it reads the supply requirement over the transmission signal), the operation manual calls it an 'indoor-outdoor unit combination fault,' and SM-TS3 calls it an 'improper combination of indoor and outdoor units.' In plain terms the two halves of the system do not agree they belong together — wrong models paired, miswired interconnects, or a wrong replacement PCB. UA on a system that has run for years almost always follows a board replacement or an added indoor unit.

Likely causes

  1. Wrong models interconnected (indoor and outdoor units not a compatible combination)
  2. Pair type and multi type units interconnected (the detection condition)
  3. Wrong wiring of the connecting wires
  4. Wrong indoor or outdoor PCB mounted (including a spare PCB whose settings were never carried out)
  5. Defective indoor or outdoor PCB

How to fix it — step by step

  1. UA is almost always an installation or board-swap finding, not a wear-out failure: start by confirming the combination — the indoor and outdoor model numbers must be a Daikin-approved pairing for the same refrigerant and type (pair vs multi). If the system was just installed or extended, this check is the diagnosis
  2. Breaker off. Verify the connecting wires are landed correctly between the units (miswired interconnects are a listed cause)
  3. If a PCB was recently replaced, check the board's code number against the model's parts list (the example format is a code like 2P01234): a wrong board — or a spare outdoor PCB whose post-replacement settings were never carried out (an SM-TS3 cause) — produces UA on an otherwise healthy system. Fit the correct board or complete its setup
  4. Check the connected indoor unit count and refrigerant type match on multi systems: excess indoor units and a refrigerant-type mismatch between indoor and outdoor units are both SM-TS3 causes
  5. If combination, wiring and board identities all prove correct, the documented remainder is a defective indoor or outdoor PCB — hand the shop the model numbers of both units and which board (if any) was previously replaced

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the UA code

Typical pro repair $450–$2,000

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.