Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) U8 Error Code

What the U8 code means

U8 is a malfunction of transmission between remote controllers — the main/sub link on systems fitted with two wired remote controllers (SM-TS3). One remote is set as main and the other as sub; U8 says that pairing has lost communication. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.

Likely causes

  1. Broken or loose main/sub remote wiring
  2. Main/sub setting wrong or duplicated after a remote was replaced
  3. Defective remote controller

How to fix it — step by step

  1. Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code) if the remotes respond; check first whether both remotes are alive — a completely dead sub remote fits this code
  2. Breaker off. Check the wiring between the two remotes and confirm the main/sub settings are one of each (two mains or two subs after a replacement is a classic cause)
  3. Restore power and re-test both remotes: control from each should work without U8 returning
  4. If settings and wiring prove correct, one remote is defective — hand a shop the pinpoint: which remote misbehaves and the main/sub configuration found

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the U8 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes

See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →