Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) UH Error Code
What the UH code means
UH is a malfunction of the system itself (SM-TS3): improper transmission wiring between the indoor and outdoor units, or a defective indoor or outdoor PCB. It is a general system-wiring/board fault, broader than U4's data-specific detection. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Improper indoor-outdoor transmission wiring
- Defective indoor unit PCB
- Defective outdoor unit PCB
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
- Breaker off. Go over the indoor-outdoor transmission wiring completely: correct terminals, no breaks, no grounds or shorts in the run — SM-TS3 puts improper wiring first for this code
- Restore power and re-test; check LED A on the outdoor PCB (blinking = its microcomputer is alive) to see which end of the link is awake
- If the wiring proves correct, UH condemns a PCB — indoor or outdoor — separated by the LED/readout behavior. Hand a shop the pinpoint: wiring verified, LED A state noted
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the indoor unit PCB.
Shop the indoor unit PCB at Amazon
Also tied to this fault: outdoor unit PCB - Shop at Amazon
Parts that commonly fix the UH code
- indoor unit PCB$80–$400Shop at Amazon
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.