Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) L5 Error Code

What the L5 code means

L5 is output overcurrent detection — SM-TS3 specifies it as inverter instantaneous overcurrent on the DC output side. The inverter has seen a current spike in what it feeds the compressor and shut down to protect its power transistors. It sits in a family with E8 (input overcurrent) and L8/L9 (inverter compressor overcurrent/startup): L5 is the instantaneous output event. Causes converge on the compressor's electrical health and the outdoor PCB's output stage.

Likely causes

  1. Instantaneous overcurrent on the inverter output (compressor drawing a current spike)
  2. Compressor failing or locked (see also E6)
  3. Defective outdoor unit PCB (power stage or its current sensing)

How to fix it — step by step

  1. Confirm L5 with the remote self-diagnosis. Stop restart attempts — an output overcurrent is the inverter catching a spike that can kill its power stage
  2. Breaker off; check the compressor harness connections (U/V/W) at the outdoor board for seating, corrosion and heat damage — a bad output connection spikes current
  3. The separation of compressor from inverter is the technician's inverter-checker diagnosis (Check No. 15 family): it determines whether the compressor drew the spike or the board imagined it
  4. If the compressor is condemned by that test, it is a sealed-system replacement; if the compressor passes, the outdoor PCB's output stage is the fault. Hand the shop the pinpoint: L5 confirmed, harness state, and whether trips are instant at start or under load → Shop the compressor at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the L5 code

Parts run $80–$1,500Typical pro repair $800–$3,000

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes

See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →