Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) L5 Error Code
What the L5 code means
L5 is output overcurrent detection — SM-TS3 specifies it as inverter instantaneous overcurrent on the DC output side. The inverter has seen a current spike in what it feeds the compressor and shut down to protect its power transistors. It sits in a family with E8 (input overcurrent) and L8/L9 (inverter compressor overcurrent/startup): L5 is the instantaneous output event. Causes converge on the compressor's electrical health and the outdoor PCB's output stage.
Likely causes
- Instantaneous overcurrent on the inverter output (compressor drawing a current spike)
- Compressor failing or locked (see also E6)
- Defective outdoor unit PCB (power stage or its current sensing)
How to fix it — step by step
- Confirm L5 with the remote self-diagnosis. Stop restart attempts — an output overcurrent is the inverter catching a spike that can kill its power stage
- Breaker off; check the compressor harness connections (U/V/W) at the outdoor board for seating, corrosion and heat damage — a bad output connection spikes current
- The separation of compressor from inverter is the technician's inverter-checker diagnosis (Check No. 15 family): it determines whether the compressor drew the spike or the board imagined it
- If the compressor is condemned by that test, it is a sealed-system replacement; if the compressor passes, the outdoor PCB's output stage is the fault. Hand the shop the pinpoint: L5 confirmed, harness state, and whether trips are instant at start or under load → Shop the compressor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Shop the outdoor unit PCB at Amazon
Also tied to this fault: compressor - Shop at Amazon
Parts that commonly fix the L5 code
- outdoor unit PCB$80–$400Shop at Amazon
- compressor$400–$1,500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.