What the L4 code means
L4 is a radiation fin temperature rise — the inverter's heatsink (the 'radiation fin' the power devices are mounted to) has run too hot (operation manual: 'high temperature at inverter circuit heatsink'). It is L3's sibling: L3 watches the electrical box air, L4 watches the inverter heatsink itself, and P4 is the fin thermistor's own fault code. Sustained high load, poor outdoor airflow, or a failing inverter stage all land here.
Likely causes
- Radiation fin (heatsink) not cooling the inverter — blocked airflow or fouled heatsink
- Sustained inverter overload heating the fin
- Defective outdoor unit PCB / fin thermistor circuit (see also P4)
How to fix it — step by step
- Confirm L4 with the remote self-diagnosis and let the unit cool — repeated hot restarts shorten inverter life
- Breaker off; inspect the outdoor unit: clean the coil and clear airflow obstructions; the heatsink sheds its heat into the same airstream the coil uses
- Check the outdoor fan runs at full speed in operation — weak airflow overheats the fin under load
- If cooling airflow is proven and L4 returns under normal load, the rise is electrical: the inverter is being over-driven or its fin temperature sensing is off (P4 is the fin thermistor's own code). The documented endpoint is the outdoor PCB assembly — hand a shop the pinpoint and whether trips happen only at peak load or immediately
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Parts that commonly fix the L4 code
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.