Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) L3 Error Code
What the L3 code means
L3 is an electrical box temperature rise (operation manual: 'electrical parts heat fault'). The outdoor unit's control box — where the inverter PCB lives — has exceeded its safe internal temperature. Heat in the box comes from restricted airflow around the outdoor unit, a struggling fan, or components on the board itself failing hot. It is a protection stop: the control is saving the inverter from cooking itself.
Likely causes
- Blocked airflow through the outdoor unit's electrical box area
- Failed cooling of the control section (fan fault upstream)
- Defective outdoor unit PCB
How to fix it — step by step
- Confirm L3 with the remote self-diagnosis. The electrical box is overheating — give the unit a rest rather than repeated restarts
- Breaker off; clear the outdoor unit's surroundings and coil: anything choking airflow around the outdoor unit raises internal temperatures (a matted coil also shows up here before it shows up as a pressure code)
- Confirm the outdoor fan actually runs in operation (a dead fan is E7's territory, but a fan problem starves the control cooling too)
- If airflow and fan are proven and L3 returns, the temperature rise is inside the box itself — failing components on the outdoor PCB generating excess heat. The documented endpoint is the outdoor PCB; hand a shop the pinpoint with the airflow state you found
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Parts that commonly fix the L3 code
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →