Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) L3 Error Code

What the L3 code means

L3 is an electrical box temperature rise (operation manual: 'electrical parts heat fault'). The outdoor unit's control box — where the inverter PCB lives — has exceeded its safe internal temperature. Heat in the box comes from restricted airflow around the outdoor unit, a struggling fan, or components on the board itself failing hot. It is a protection stop: the control is saving the inverter from cooking itself.

Likely causes

  1. Blocked airflow through the outdoor unit's electrical box area
  2. Failed cooling of the control section (fan fault upstream)
  3. Defective outdoor unit PCB

How to fix it — step by step

  1. Confirm L3 with the remote self-diagnosis. The electrical box is overheating — give the unit a rest rather than repeated restarts
  2. Breaker off; clear the outdoor unit's surroundings and coil: anything choking airflow around the outdoor unit raises internal temperatures (a matted coil also shows up here before it shows up as a pressure code)
  3. Confirm the outdoor fan actually runs in operation (a dead fan is E7's territory, but a fan problem starves the control cooling too)
  4. If airflow and fan are proven and L3 returns, the temperature rise is inside the box itself — failing components on the outdoor PCB generating excess heat. The documented endpoint is the outdoor PCB; hand a shop the pinpoint with the airflow state you found

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the L3 code

Parts run $80–$400Typical pro repair $450–$2,000Fixing it yourself typically saves $50–$1,920

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.