Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) J4 Error Code
What the J4 code means
J4 is a malfunction of the low-pressure equivalent saturated temperature sensor system (SM-TS3). Rather than a single named thermistor, J4 indicts the sensor system the control uses to derive the low-side saturation temperature — the computed value behind low-pressure protection and capacity control on sensor-based models. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Defective sensor in the low-pressure saturation sensing chain
- Sensor connector/wiring fault
- Defective outdoor unit PCB
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
- Breaker off. Check the connectors of the outdoor sensor group (pressure and temperature sensors feeding this calculation) for seating and damage
- The technician separates the chain by testing each contributing sensor against its chart/gauge and comparing the derived value with a real gauge reading; the sensor that disagrees is replaced
- Hand a shop this pinpoint: J4 confirmed, connectors verified, and any companion sensor codes (J1/J5/J6) the readout offered — they narrow the chain
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure sensor.
Shop the pressure sensor at Amazon
Also tied to this fault: outdoor unit PCB - Shop at Amazon
Parts that commonly fix the J4 code
- pressure sensorShop at Amazon
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes