Amana Furnace GMES80 (PCBBF145 control board) LED off

What this problem usually means

The control board shows no diagnostic signal. There is no 115 volt power to the furnace, no 24 volt power to the integrated control module, or the control module has an internal fault.

Likely causes

  1. Manual disconnect switch off or blower door switch open
  2. Blown 3 amp fuse on the control board or tripped circuit breaker
  3. 24 volt wires loose or connected wrong
  4. Integrated control module failed internally

How to fix it — step by step

  1. Turn the power off at the disconnect before opening any panel.
  2. Read the code through the observation window in the blower door first. The LED is on the control board in the blower compartment.
  3. Check the disconnect switch, the door switch, and the breaker. Restore any that are off or tripped.
  4. Remove the blower door and find the 3 amp automotive style fuse on the control board. Pull it and check it. A blown fuse means replace it with a 3 amp fuse and then find the short in the 115 volt or 24 volt wiring that blew it. → Shop the control board fuse at Amazon
  5. Measure 115 volts and 24 volts at the control module with a meter. Correct voltage present with no LED means the module itself has failed.
  6. If power and fuse are good and the LED stays dark, replace the integrated control module. Call a pro if you are not set up to test live voltage.
  7. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $125–$585Typical pro repair $200–$600

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Amana Furnace GMES80 (PCBBF145 control board) problems

See all Amana GMES80 (PCBBF145 control board) codes & guides →