Amana Furnace GMES80 (PCBBF145 control board) 5 flashes

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Flame sensed with no call for heat. The control sees a flame signal while the gas valve is off, so it runs both blowers continuously and stops furnace operation.

Likely causes

  1. Short to ground in the flame sense circuit
  2. Lingering burner flame after shutdown
  3. Slow closing gas valve leaking gas to the burners
  4. Miswired flame sensor circuit

How to fix it — step by step

  1. Treat this as a gas safety fault. Turn the power off and close the gas shutoff to the furnace.
  2. If you smell gas, leave the building and call the gas supplier from outside. Do not keep working on the furnace.
  3. With the gas off, find the flame sensor rod in the burner area and inspect its wire for chafed insulation touching the cabinet. A grounded sensor wire fakes a flame signal.
  4. Check that the burners are fully out. Flame still present with the valve off means the gas valve is leaking through.
  5. Do not reset and run this furnace. A leaking or slow closing gas valve is replaced, not adjusted, and that is pro work.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $200–$600

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.