Amana Furnace GMES80 (PCBBF145 control board) 3 flashes

What it should look like on your machine

then it repeats

3 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Pressure switch stuck open. The inducer runs but the pressure switch never closes, so ignition is blocked. If it stays open for five minutes the control goes into a one hour lockout.

Likely causes

  1. Pressure switch hose blocked, pinched, or connected wrong
  2. Blocked flue pipe or blocked combustion air inlet pipe
  3. Weak or failed induced draft blower
  4. Wrong pressure switch setpoint or failed switch contacts
  5. Loose wiring at the switch

How to fix it — step by step

  1. Turn the power off before opening any panel.
  2. Find the pressure switch near the inducer and pull its rubber hose. Blow through it gently and check the port on the inducer housing for debris. A plugged port is a common cause.
  3. Go outside and check the flue and intake terminations for snow, nests, or debris. Clear any blockage.
  4. Restore power and call for heat. If the inducer does not run at all, the fault is the inducer or its power supply, not the switch.
  5. If the inducer runs strong and the vent is clear, test the switch with a meter during the inducer run. No closure with good draft means the switch has failed.
  6. Replace the pressure switch with the correct setpoint part if it will not close under proven draft. Call a pro if draft itself is weak, since that points to the inducer or vent sizing.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $50–$205Typical pro repair $133–$505

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.