Amana GMES80 (PCBBF145 control board) Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 10 problems covered.

Not sure of the code? Tap along with it

If your Amana Furnace blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
1 flashSystem lockout. The furnace tried to light three times and never proved flame, so the control locked out. It…No gas reaching the burners›
2 flashesPressure switch stuck closed. The control sees the pressure switch closed while the induced draft blower is…Pressure switch contacts sticking closed›
3 flashesPressure switch stuck open. The inducer runs but the pressure switch never closes, so ignition is blocked. If…Pressure switch hose blocked, pinched, or connected wrong›
4 flashesOpen primary limit. The high limit switch opened because the heat exchanger got too hot, usually from low…Dirty or blocked air filter›
5 flashesFlame sensed with no call for heat. The control sees a flame signal while the gas valve is off, so it runs…Short to ground in the flame sense circuit›
6 flashesOpen rollout limit. The rollout switch above the burners opened, which means flame or excess heat escaped the…Blocked flue pipe or blocked air inlet pipe›
7 flashesLow flame sense signal. The furnace keeps running, but the flame signal from the sensor has dropped below the…Flame sensor coated or oxidized›
8 flashesIgniter circuit fault or poor ground. The control cannot run the igniter correctly, so the furnace fails to…Igniter connected wrong or loose igniter plug›
Continuous rapid flashReversed polarity. The 115 volt power to the furnace or the 24 volt transformer wiring is reversed, or the…Line and neutral reversed at the furnace junction box›
LED offThe control board shows no diagnostic signal. There is no 115 volt power to the furnace, no 24 volt power to…Manual disconnect switch off or blower door switch open›

All Amana furnace models & codes →