Amana GMES80 (PCBBF145 control board) Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 10 problems covered.
Not sure of the code? Tap along with it
If your Amana Furnace blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 flash | System lockout. The furnace tried to light three times and never proved flame, so the control locked out. It… | No gas reaching the burners | › |
| 2 flashes | Pressure switch stuck closed. The control sees the pressure switch closed while the induced draft blower is… | Pressure switch contacts sticking closed | › |
| 3 flashes | Pressure switch stuck open. The inducer runs but the pressure switch never closes, so ignition is blocked. If… | Pressure switch hose blocked, pinched, or connected wrong | › |
| 4 flashes | Open primary limit. The high limit switch opened because the heat exchanger got too hot, usually from low… | Dirty or blocked air filter | › |
| 5 flashes | Flame sensed with no call for heat. The control sees a flame signal while the gas valve is off, so it runs… | Short to ground in the flame sense circuit | › |
| 6 flashes | Open rollout limit. The rollout switch above the burners opened, which means flame or excess heat escaped the… | Blocked flue pipe or blocked air inlet pipe | › |
| 7 flashes | Low flame sense signal. The furnace keeps running, but the flame signal from the sensor has dropped below the… | Flame sensor coated or oxidized | › |
| 8 flashes | Igniter circuit fault or poor ground. The control cannot run the igniter correctly, so the furnace fails to… | Igniter connected wrong or loose igniter plug | › |
| Continuous rapid flash | Reversed polarity. The 115 volt power to the furnace or the 24 volt transformer wiring is reversed, or the… | Line and neutral reversed at the furnace junction box | › |
| LED off | The control board shows no diagnostic signal. There is no 115 volt power to the furnace, no 24 volt power to… | Manual disconnect switch off or blower door switch open | › |
All Amana furnace models & codes →