Amana Furnace GMES80 (PCBBF145 control board) 1 flash

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

System lockout. The furnace tried to light three times and never proved flame, so the control locked out. It resets on its own after one hour.

Likely causes

  1. No gas reaching the burners
  2. Pressure switch stuck open so ignition never starts
  3. Bad igniter or igniter out of alignment
  4. Flame sensor coated, oxidized, or connected wrong
  5. Flame lights then drops out from low gas pressure or a restricted flue

How to fix it — step by step

  1. Turn the power off and close the gas shutoff to the furnace before working inside it.
  2. Confirm the manual gas shutoff valve in the line to the furnace is open and other gas appliances in the home work. No gas anywhere points to the supply, not the furnace.
  3. Remove the burner door and find the hot surface igniter in front of the burners. Look for cracks or white burn marks. A cracked igniter will not glow and must be replaced. → Shop the hot surface igniter at Amazon
  4. Find the flame sensor, a single metal rod in the burner flame path held by one screw. Remove it and clean the rod with fine steel wool until the metal is bright. A clean sensor that still drops flame points to gas pressure or venting.
  5. Restore power and call for heat. Watch one full try. Inducer runs, igniter glows, gas valve clicks, flame lights. The step where the sequence stops is the failed part.
  6. If the igniter glows and gas flows but flame still is not proved after cleaning the sensor, stop and call a pro to check gas pressure and the gas valve.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $150–$500

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Amana Furnace GMES80 (PCBBF145 control board) problems

See all Amana GMES80 (PCBBF145 control board) codes & guides →