Amana Furnace GMES80 (PCBBF145 control board) Continuous rapid flash

What this problem usually means

Reversed polarity. The 115 volt power to the furnace or the 24 volt transformer wiring is reversed, or the unit ground is poor. The furnace fails to operate.

Likely causes

  1. Line and neutral reversed at the furnace junction box
  2. Orange and gray transformer wires reversed
  3. Poor or missing equipment ground

How to fix it — step by step

  1. Turn the power off at the breaker before opening the junction box. This is line voltage wiring.
  2. Open the furnace junction box and identify the black line wire and white neutral wire feeding the furnace.
  3. Test with a meter. Black to ground should read about 120 volts and white to ground should read near zero. Readings the other way round confirm reversed polarity.
  4. Correct the line and neutral connections to match the wiring diagram inside the door.
  5. Check the transformer orange and gray wires against the diagram and swap them back if they are reversed.
  6. Verify the ground wire is bonded to the cabinet. If you are not qualified for line voltage work, call an electrician or HVAC pro to correct the wiring.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Amana Furnace GMES80 (PCBBF145 control board) problems

See all Amana GMES80 (PCBBF145 control board) codes & guides →