Amana Furnace GMES80 (PCBBF145 control board) 2 flashes

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Pressure switch stuck closed. The control sees the pressure switch closed while the induced draft blower is off, so it will not start a heat cycle.

Likely causes

  1. Pressure switch contacts sticking closed
  2. Short in the pressure switch wiring
  3. Pressure switch hose blocked or pinched holding pressure on the switch

How to fix it — step by step

  1. Turn the power off before opening the blower or burner compartment.
  2. Find the pressure switch. It is a round switch near the inducer with a rubber hose and two wires.
  3. Pull the rubber hose off the switch and check it is clear and not holding water or debris. A blocked hose can hold the switch closed.
  4. With the inducer off, test the switch contacts with a meter set to continuity. Contacts closed with no inducer running means the switch is stuck.
  5. Check the two switch wires for a short or pinched insulation. Repair any damaged wire.
  6. If the hose and wiring are good and the contacts stay closed, replace the pressure switch with the correct setpoint part.
  7. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $50–$205Typical pro repair $133–$505
  • pressure switch$50–$205Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.