Amana Furnace GMES80 (PCBBF145 control board) 6 flashes
What it should look like on your machine
then it repeats
6 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Open rollout limit. The rollout switch above the burners opened, which means flame or excess heat escaped the burner compartment. The circulator blower runs continuously.
Likely causes
- Blocked flue pipe or blocked air inlet pipe
- Misaligned burners
- Failed induced draft blower so draft is lost
- Faulty rollout limit switch
- Loose wiring in the rollout circuit
How to fix it — step by step
- Turn the power off and close the gas shutoff. Do not reset the rollout switch and restart the furnace until the cause is found. Rollout means flame went where it should not go.
- Look for scorch marks or melted wire insulation above the burners. Damage there confirms real rollout happened.
- Check the flue and intake pipes end to end for blockage, including the outdoor terminations.
- Restore power briefly and call for heat to confirm the inducer starts and pulls draft. An inducer that does not run explains the rollout.
- Find the rollout switch above the burners. It is a small disc switch with a reset button on some models. Test it with a meter. Open when cool after the vent and inducer check out means the switch itself failed.
- If the vent is clear and the inducer runs and the switch still trips, stop and call a pro. Repeated rollout can mean a damaged heat exchanger.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the rollout limit switch.
Shop the rollout limit switch at Amazon
Also tied to this fault: induced draft blower - Shop at Amazon
Parts that commonly fix it
- rollout limit switch$5–$35Shop at Amazon
- induced draft blowerShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.