Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) Over Crank

What this problem usually means

Three unsuccessful starting attempts. The engine cranked but never started, and the controller stopped trying to protect the starter and battery.

Likely causes

  1. Fuel supply off, empty or interrupted
  2. Spark plug fouled or failed
  3. Battery too weak to crank at starting speed
  4. Loose connections

How to fix it — step by step

  1. Safety first: the set is outdoors only. Never run or crank-test a generator indoors or in a garage, and keep exhaust pointed away from windows and doors. Carbon monoxide is odorless and deadly.
  2. Check the fuel supply first: fuel valve open, propane tank not empty, and the correct fuel source selected. Opening a found closed valve and the set starting is the fix for this branch.
  3. Check the spark plug and the battery, and check for loose connections at the battery and starter. A fouled plug replaced, or a weak battery charged or replaced, followed by a clean start, completes those branches.
  4. If fuel, plug, battery and connections are all proven and the set still will not start after three attempts, stop cranking. The pinpoint is in the fuel or ignition system and it is dealer service. Report Over Crank and what you already checked.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$150

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) problems

See all Kohler 14/20RESA, 14/20RESAL (RDC2/DC2 controller) codes & guides →