Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) Battery Voltage High
What this problem usually means
Engine starting battery voltage has risen above 16 VDC for more than 10 seconds. The check is inhibited during the engine crank cycle and clears when battery voltage returns to an acceptable level.
Likely causes
- Battery charger overcharging
- Wrong battery rating or a failed battery
How to fix it — step by step
- Measure or read the battery voltage at rest at the starting battery inside the enclosure. Sustained voltage above 16 VDC confirms overcharge, not a display error.
- Check the battery rating and condition. A correct, healthy battery that still sits above 16 VDC moves the pinpoint to the charger. → Shop the battery charger at Amazon
- Check the battery charger operation. Voltage that high points to a charger regulation fault when the battery itself is proven good, and that is dealer service. Do not leave an overcharging battery in service, since it will be damaged.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Battery.
Also tied to this fault: Battery charger - Shop at Amazon
Parts that commonly fix it
- Battery$50–$150Shop at Amazon
- Battery charger$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) problems
- Battery Voltage Low
- Engine Oil Pressure Low
- EngineSpeed High
- EngineSpeed Low
- Fails Exercise
- Generator Frequency Low
- Generator Voltage L1-L2 Low
- Lo Crank Vlt
- Locked Rotor
- Over Crank
- Won't Start
- Won't Turn On
See all Kohler 14/20RESA, 14/20RESAL (RDC2/DC2 controller) codes & guides →