Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) AC Sens Lost
What this problem usually means
AC sensing is lost. Detection starts 10 seconds after crank disconnect. It is a warning after 1 second if no output is detected after crank disconnect, and a shutdown after 3 seconds if voltage was present and then lost.
Likely causes
- Generator output AC sensing lost
- No generator output after crank disconnect
- Output voltage present and then lost
How to fix it — step by step
- Read the display on the RDC2/DC2 controller on the generator set. Access is at the controller face, no covers off. Note whether the message is the 1-second warning form or the shutdown form.
- Check that the engine is actually running and producing output when the message appears. A running engine with no output and a shutdown form of this message pinpoints lost AC sensing or lost output, not a starting problem.
- Do not keep resetting and restarting against a repeating shutdown. The pinpoint is the AC sensing/output path, which is dealer service work. Report the exact message, AC Sens Lost.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Controller.
Parts that commonly fix it
- ControllerShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) problems
- ATS Com Error
- Battery Voltage High
- Battery Voltage Low
- Engine Oil Pressure Low
- EngineSpeed High
- EngineSpeed Low
- Fails Exercise
- Generator Frequency Low
- Generator Voltage L1-L2 Low
- Lo Crank Vlt
- Locked Rotor
- Over Crank
See all Kohler 14/20RESA, 14/20RESAL (RDC2/DC2 controller) codes & guides →