Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) AC Sens Lost

What this problem usually means

AC sensing is lost. Detection starts 10 seconds after crank disconnect. It is a warning after 1 second if no output is detected after crank disconnect, and a shutdown after 3 seconds if voltage was present and then lost.

Likely causes

  1. Generator output AC sensing lost
  2. No generator output after crank disconnect
  3. Output voltage present and then lost

How to fix it — step by step

  1. Read the display on the RDC2/DC2 controller on the generator set. Access is at the controller face, no covers off. Note whether the message is the 1-second warning form or the shutdown form.
  2. Check that the engine is actually running and producing output when the message appears. A running engine with no output and a shutdown form of this message pinpoints lost AC sensing or lost output, not a starting problem.
  3. Do not keep resetting and restarting against a repeating shutdown. The pinpoint is the AC sensing/output path, which is dealer service work. Report the exact message, AC Sens Lost.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Kohler Generator 14/20RESA, 14/20RESAL (RDC2/DC2 controller) problems