Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) A6 Error Code
What the A6 code means
A6 is an indoor fan motor abnormality. The control watches the fan's rotation speed through its Hall sensor; when the detected speed fails to reach the target and sits under 50% of maximum fan speed, A6 is set (service manual SiUS091133). On the FTXS DC-motor units the documented causes are internal motor faults — a layer short in the winding, a broken wire inside the motor or its leads — or the indoor PCB; the FDXS AC-motor variants add a failed fan capacitor and low supply voltage. The fan itself is behind the indoor unit's front panel and filters; the confirming voltage checks involve 310-340 VDC at the motor connector, which is why the fix ends at a pinpoint for a technician.
Likely causes
- Layer short inside the fan motor winding
- Broken wire inside the fan motor or in its lead wires
- Failed fan motor capacitor (AC-motor models)
- Reduced power supply voltage (FDXS AC-motor models)
- Defective indoor unit PCB
How to fix it — step by step
- Confirm A6 with the remote self-diagnosis. Note whether the fan never starts, starts and stalls, or runs slowly — the decision is speed under half of maximum, so a weak fan is still this code
- Breaker OFF, then rotate the fan by hand (Daikin's first physical check): it should spin smoothly. A fan that is stiff, gritty or blocked gets its obstruction cleared or is condemned mechanically. Warning from the manual: never disconnect the fan motor connector while power is supplied
- Power on and start operation: does the fan rotate at all? A fan that runs normally after the hand check may have been a transient; one that still will not reach speed goes to the electrical checks
- The confirming tests are a technician's (the motor supply is 310-340 VDC): Check No. 02 measures the fan motor connector output — motor power supply voltage, the 15 VDC control voltage, the 1-5 VDC rotation command and the rotation pulse. Supply and command present with no rotation condemns the indoor fan motor; absent supply or command condemns the indoor PCB
- Hand a shop this pinpoint: A6 confirmed, hand-spin result noted, and whether the fan attempts rotation at power-on — that separates motor from board before anyone orders parts
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the indoor fan motor.
Shop the indoor fan motor at Amazon
Also tied to this fault: indoor unit PCB - Shop at Amazon
Parts that commonly fix the A6 code
- indoor fan motorShop at Amazon
- indoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →