Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) H7 Error Code
What the H7 code means
H7 is a malfunction of the outdoor unit fan motor signal (SM-TS3); Daikin's owner-manual list adds 'fan motor overloaded / overcurrent / sensor abnormal.' It is E7's sibling: E7 is the fan failing to start (lock), H7 is the fan motor's signal — its speed feedback or electrical behavior — going wrong on a fan that may still turn. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Defective outdoor fan motor (signal/feedback section)
- Fan motor overloaded or overcurrent condition
- Defective outdoor unit PCB
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
- Breaker OFF before going near the outdoor fan. Clear anything in or around the blades and confirm the fan spins freely by hand — a dragging fan overloads its motor and produces this signal fault
- Check the fan motor connector is fully seated (power off) and its leads undamaged
- Restore power and observe: a fan that runs smoothly but still sets H7 has a feedback/signal fault (motor or board); a fan that labors or stalls has the overload the owner manual names. The outdoor PCB rotation-pulse check (Check No. 16 in the E7 flow) separates them
- Hand a shop this pinpoint: H7 confirmed, fan free by hand, connector seated, and how the fan actually behaves at run
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the outdoor fan motor.
Shop the outdoor fan motor at Amazon
Also tied to this fault: outdoor unit PCB - Shop at Amazon
Parts that commonly fix the H7 code
- outdoor fan motor$80–$300Shop at Amazon
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →