Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) C6 Error Code
What the C6 code means
C6 is a malfunction of the fan motor sensor or the fan control driver (SM-TS3) — the sensing/driving electronics for the indoor fan, as distinct from A6, which is the fan motor abnormality detection itself. C6 points one step earlier in the chain: the Hall sensor that reports fan speed, or the driver that powers the fan. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Defective fan motor speed (Hall) sensor
- Defective fan control driver on the indoor PCB
- Fan motor connector/wiring fault
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code). Note the fan's behavior: running but misreported, or not running at all — it separates sensor from driver
- Breaker off. Check the fan motor connector and its leads at the indoor board (the A6 flow's connector checks apply here too)
- Restore power and observe: a fan that runs at correct speeds while C6 persists has a sensing fault (sensor/board); a fan that never gets drive has a driver fault. Both end at the indoor PCB/fan motor pair, separated by the technician's connector-output checks (the A6 page lists the voltages)
- Hand a shop this pinpoint: C6 confirmed, fan's actual behavior, connector verified
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the indoor fan motor.
Shop the indoor fan motor at Amazon
Also tied to this fault: indoor unit PCB - Shop at Amazon
Parts that commonly fix the C6 code
- indoor fan motorShop at Amazon
- indoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.