Bosch Water heater Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 18 codes covered.

Finding your model number: it is on the unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

All models

ProblemWhat it meansCheck first
Won't Turn OnA Bosch tankless heater (Therm / Greentherm family) that will not turn on is electric before it is anything…No house power: tripped breaker, or the unit's ON/OFF switch (behind the flip-down›

Therm 6000 S

CodeWhat it meansCheck first
A2Fault in the flue gas limiter: temperature inside the cabinet rose above 110 C and the flue gas limiter…Flue gas leaking around the top or bottom seals of the heat exchanger›
A3Resistance connections are not correct: the control detected an incorrect resistance connection (the fixed…Resistance connection loose, missing or incorrect at the control (see Fig. 2, item 9 in›
A4Backflow temperature sensor defect: the backflow temperature sensor is disconnected or short-circuited.Backflow temperature sensor disconnected›
A7Outlet temperature sensor fault: the outlet (hot water) temperature sensor read below 0 C or above 98 C.Corroded or loose red wire connections at the hot water temperature sensor›
A9Outlet temperature sensor is not sensing the expected output temperature. This flashing display is a status…Sensor not firmly attached to the hot water pipe, or mounted on a pipe bend and›
C6Primary fan rotation too low in operation: the combustion fan is turning slower than it should while the…Loose fan wire connections (back of fan or the two control board connectors)›
C7No rotational speed sensor signal from the primary fan: the control cannot confirm the fan is turning.Loose fan wire connections (back of fan or the two control board connectors)›
CAWater flow signal over the specified maximum value: the flashing CA display means measured water flow is…Excessive water pressure and flow through the heater›
E0Software/hardware failure in the control unit.Loose wire or ground connections on the control board or heater chassis›
E1Hot water over-temperature: the hot water temperature sensor (NTC) at the exit of the appliance detected hot…NTC sensor loose or incorrectly positioned/fixed›
E2Cold water temperature sensor fault: the inlet temperature sensor is not reading correctly.Loose connector on the wires coming from the top of the water valve›
E4Backflow temperature sensor over 140 C: the appliance closed the burner and locked out (non-volatile lock).Blocked or incorrectly specified inlet/outlet vent pipes›
E9Overheat sensor (ECO) open circuit: the overheat protection opened; it resets when cooler temperatures are…Loose or corroded white wire connections at the overheat sensor or control board›
EANo flame ionization detected with water flow: water is flowing and the unit is sparking, but no flame is…Manual gas shut-off valves closed or no gas supply›
ECIonization failure during operation: flame was established but ionization (flame sensing) was lost while the…Wrong gas type›
F7Ionization error at standby: the flame ionization rod is signalling flame while the unit is at standby, when…Loose connection to the flame ionization rod›
FAGas leakage error: the gas valve circuit is not closing properly, so the control treats it as a gas leakage…Loose wire connections on the gas valve or the two control board connectors›
Looking for a part?

Once you know the part you need, browse Bosch Water heater replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.