Bosch Water heater Won't Turn On

What this problem usually means

A Bosch tankless heater (Therm / Greentherm family) that will not turn on is electric before it is anything else: the control, fan and igniter run on house power, and the unit only attempts ignition when it sees water flow above its minimum activation rate — so a Bosch can be fully powered and still 'not turn on' at a barely-open tap. Split it in three: display dark = no power to the control (breaker, the unit's power switch behind the front cover strip, or the control unit's internal fuses, whose location is in the electrical section). Display lit, tap fully open, no ignition attempt = the flow sensor is not registering flow (clogged inlet filter, a valve not fully open, or flow genuinely below the activation minimum). Display lit with an ignition attempt that fails = the unit reports an error code (the EA/no-flame family) — that is a code page, not a no-power page. There is also a reset button for lockout conditions and a high-temperature thermal cutout that, once tripped by overheating, stops the heater until it is reset, with the power disconnected and the cover removed.

Likely causes

  1. No house power: tripped breaker, or the unit's ON/OFF switch (behind the flip-down cover on the front panel strip) set to OFF
  2. Blown fuse in the control unit — the fuse position is in the electrical-connections section
  3. Flow below the minimum activation rate, a clogged cold-water inlet filter, or an isolation/service valve not fully open — the unit never gets the start signal
  4. Tripped high-temperature thermal cutout after an overheat — reset only with power disconnected and the cover off
  5. Failed flow sensor/switch: full flow at the tap, filter clean, still no ignition attempt
  6. Failed control board: power proven at the unit, display still dark

How to fix it — step by step

  1. Prove house power and the unit's own switch first: check the breaker for the heater's circuit, and find the ON/OFF switch — on Bosch tankless models it sits behind the flip-down cover plate on the front panel strip; OFF there makes a powered unit look dead. Restore both and watch for the display
  2. Run the flow test before opening anything: open one hot tap FULLY. A tankless unit does nothing below its minimum activation flow, so a trickling tap is not a test. Full flow + a lit display + no fan and no ignition sounds = the unit is not seeing flow — go to step 3. Full flow + ignition attempts (fan, clicking) that fail = the unit is reporting an error code; note it and work that code's page instead
  3. Clear the flow path: close the isolation valves, remove and rinse the cold-water inlet filter/screen at the unit's inlet (sediment there is the common cause), and confirm both service/isolation valves are fully open afterwards — Bosch's flow checks start with the inlet and service valves fully open. Retest with the tap fully open
  4. If the unit overheated before dying (a scalding episode, an overheat code, or a shutdown during heavy use), the thermal cutout is the suspect: Bosch's procedure is power DISCONNECTED, front cover removed, press the reset button in the centre of the high-temperature cutout, cover back, power restored. That is the one internal owner step — if the cutout trips again, the overheating cause (scale-restricted heat exchanger, failing sensor) is a technician's diagnosis, not another reset
  5. Display still dark with the breaker proven: the control unit's fuses are next — The fuses have a dedicated position layout in the control unit for exactly this check. Fuse testing inside the control unit is technician work (the cover comes off a gas appliance); the pinpoint to hand over is 'line power proven at the unit, display dark — control-unit fuse or control board' → Shop the control board at Amazon
  6. Flow proven, filter clean, valves open, still no ignition attempt with a lit display = the flow sensor/switch has failed — it is the part that tells the control water is moving, located at the cold inlet inside the unit. That is the terminal pinpoint; its replacement is technician work on a gas/water appliance → Shop the flow sensor at Amazon
  7. Verify with a real draw: one hot tap fully open, fan runs, burner lights, outlet temperature reaches the setpoint and holds while the tap runs — then a second tap opened to confirm it modulates rather than dropping out

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.