Bosch Water heater Therm 6000 S A4 Error Code

What the A4 code means

Backflow temperature sensor defect: the backflow temperature sensor is disconnected or short-circuited.

Likely causes

  1. Backflow temperature sensor disconnected
  2. Backflow temperature sensor short-circuited/failed

How to fix it — step by step

  1. The backflow temperature sensor is item 13 in the component figure (Fig. 2) — on the exhaust/flue path at the top of the unit, reached with the front cover off, with a plug connector on its lead to the control.
  2. Check the backflow temperature sensor connection and reseat it: a disconnected plug is the first named cause, and reseating it on a clean terminal clears a connection fault outright.
  3. If the connection is sound, test the split: a sensor whose lead is shorted (chafed against the flue or cabinet) reads as a short-circuit fault — inspect the lead run; a sound lead with the fault persisting condemns the sensor.
  4. Replace the exhaust temperature sensor assembly per the solution: power and gas off, connector unplugged, the sensor unclipped/unthreaded from its mount on the flue path, the new assembly fitted and plugged in. → Shop the exhaust temperature sensor at Amazon
  5. Prove a full heating cycle with no A4.
  6. If you hand it over, tell the technician: A4 — backflow temperature sensor disconnected or short-circuited — with its connection already reseated.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - A4 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the A4 code

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bosch Water heater Therm 6000 S error codes

See all Bosch Therm 6000 S codes & guides →