Bosch Water heater Therm 6000 S EA Error Code

What the EA code means

No flame ionization detected with water flow: water is flowing and the unit is sparking, but no flame is being sensed - ignition failed.

Likely causes

  1. Manual gas shut-off valves closed or no gas supply
  2. Wrong gas type
  3. Gas pressure incorrect or air in the gas line
  4. Loose connections in the three wires on the lower front of the heat exchanger
  5. Venting out of specification damaging the flame sensor rod
  6. Minimum power fan speed incorrectly adjusted

How to fix it — step by step

  1. Verify all manual gas shut-off valves are open.
  2. Check gas type and gas pressure.
  3. Reset the error and open a water tap to cycle the heater and purge air, cycling the tap on and off several times if needed; if EA persists, a licensed gas technician should purge air from the gas line to the heater.
  4. Check the three wire connections on the lower front of the heat exchanger are secure — that is where the ignition group (spark and flame sensor rod) lands, behind the front cover at the bottom of the exchanger.
  5. Verify venting meets specifications — improper venting can cause premature failure of the flame sensor rod.
  6. Check the minimum power fan speed is adjusted to the proper value (manual chapter 8.6).
  7. Watch through the viewing window on a call for heat: sparking should be followed by a steady blue flame; an unstable/yellow flame with correct gas pressure requires CO2 readings to be confirmed (technician combustion work). Sparking with no flame at all, on proven gas, condemns the flame sensor rod: it is replaced at the ignition group — power and gas off, its wire disconnected, the rod unclipped from the exchanger front, the new rod fitted at the same insertion depth.
  8. If you hand it over, tell the technician: EA — sparking but no flame sensed — and what the viewing window showed.
  9. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - EA should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the EA code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bosch Water heater Therm 6000 S error codes

See all Bosch Therm 6000 S codes & guides →