Bosch Water heater Therm 6000 S EC Error Code

What the EC code means

Ionization failure during operation: flame was established but ionization (flame sensing) was lost while the burner was running.

Likely causes

  1. Wrong gas type
  2. Gas pressure incorrect
  3. Loose connections to the ignition group on the lower front of the heat exchanger
  4. Venting out of specification damaging the flame sensor rod
  5. Minimum power fan speed incorrectly adjusted
  6. CO2 settings out of adjustment

How to fix it — step by step

  1. Check gas type and gas pressure.
  2. Check the three wire connections to the ignition group on the lower front of the heat exchanger are secure (front cover off, bottom of the exchanger).
  3. Verify venting meets specifications — improper venting can cause premature failure of the flame sensor rod.
  4. Check the minimum power fan speed is adjusted to the proper value (manual chapter 8.6).
  5. Check and adjust the CO2 readings (combustion analyser work — a technician step if you have no analyser).
  6. Replace the flame sensor rod if connections and settings are correct but ionisation still drops out: power and gas off, its wire disconnected at the ignition group, the rod unclipped and withdrawn, the new rod fitted at the same depth and reconnected. → Shop the flame sensor rod at Amazon
  7. Prove repeated full heating cycles with no EC drop-out.
  8. If you hand it over, tell the technician: EC — flame established but ionisation lost during operation — with the ignition-group connections already checked.
  9. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - EC should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the EC code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bosch Water heater Therm 6000 S error codes

See all Bosch Therm 6000 S codes & guides →