Bosch Therm 6000 S Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 17 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| A2 | Fault in the flue gas limiter: temperature inside the cabinet rose above 110 C and the flue gas limiter… | Flue gas leaking around the top or bottom seals of the heat exchanger | › |
| A3 | Resistance connections are not correct: the control detected an incorrect resistance connection (the fixed… | Resistance connection loose, missing or incorrect at the control (see Fig. 2, item 9 in | › |
| A4 | Backflow temperature sensor defect: the backflow temperature sensor is disconnected or short-circuited. | Backflow temperature sensor disconnected | › |
| A7 | Outlet temperature sensor fault: the outlet (hot water) temperature sensor read below 0 C or above 98 C. | Corroded or loose red wire connections at the hot water temperature sensor | › |
| A9 | Outlet temperature sensor is not sensing the expected output temperature. This flashing display is a status… | Sensor not firmly attached to the hot water pipe, or mounted on a pipe bend and | › |
| C6 | Primary fan rotation too low in operation: the combustion fan is turning slower than it should while the… | Loose fan wire connections (back of fan or the two control board connectors) | › |
| C7 | No rotational speed sensor signal from the primary fan: the control cannot confirm the fan is turning. | Loose fan wire connections (back of fan or the two control board connectors) | › |
| CA | Water flow signal over the specified maximum value: the flashing CA display means measured water flow is… | Excessive water pressure and flow through the heater | › |
| E0 | Software/hardware failure in the control unit. | Loose wire or ground connections on the control board or heater chassis | › |
| E1 | Hot water over-temperature: the hot water temperature sensor (NTC) at the exit of the appliance detected hot… | NTC sensor loose or incorrectly positioned/fixed | › |
| E2 | Cold water temperature sensor fault: the inlet temperature sensor is not reading correctly. | Loose connector on the wires coming from the top of the water valve | › |
| E4 | Backflow temperature sensor over 140 C: the appliance closed the burner and locked out (non-volatile lock). | Blocked or incorrectly specified inlet/outlet vent pipes | › |
| E9 | Overheat sensor (ECO) open circuit: the overheat protection opened; it resets when cooler temperatures are… | Loose or corroded white wire connections at the overheat sensor or control board | › |
| EA | No flame ionization detected with water flow: water is flowing and the unit is sparking, but no flame is… | Manual gas shut-off valves closed or no gas supply | › |
| EC | Ionization failure during operation: flame was established but ionization (flame sensing) was lost while the… | Wrong gas type | › |
| F7 | Ionization error at standby: the flame ionization rod is signalling flame while the unit is at standby, when… | Loose connection to the flame ionization rod | › |
| FA | Gas leakage error: the gas valve circuit is not closing properly, so the control treats it as a gas leakage… | Loose wire connections on the gas valve or the two control board connectors | › |
All Bosch water heater models & codes →