Bosch Water heater Therm 6000 S E2 Error Code

What the E2 code means

Cold water temperature sensor fault: the inlet temperature sensor is not reading correctly.

Likely causes

  1. Loose connector on the wires coming from the top of the water valve
  2. Sensor tripped by water temperature below 2 C (freeze conditions)
  3. Failed cold water temperature sensor

How to fix it — step by step

  1. Check the connector on the wires coming from the top of the water valve for a secure connection.
  2. If the heater was exposed to freezing, protect it from freezing conditions and check for damage.
  3. Test the sensor and replace the cold water temperature sensor if it reads out of specification. → Shop the cold water temperature sensor at Amazon
  4. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - E2 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E2 code

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bosch Water heater Therm 6000 S error codes

See all Bosch Therm 6000 S codes & guides →