Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) 8 flashes

What it should look like on your machine

then it repeats

8 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Lockout due to too many flame dropouts. Flame lit, then was lost too many times in one call for heat.

Likely causes

  1. Dirty flame sensor losing the signal
  2. Low or interrupted gas pressure
  3. Weak draft lifting the flame off the sensor
  4. Faulty gas valve dropping out

How to fix it — step by step

  1. Turn the power off before removing parts.
  2. Clean the flame sensor rod with fine steel wool until bright. Repeated dropouts are most often a coated sensor.
  3. Check the vent and intake for partial blockage that weakens draft mid cycle.
  4. Restore power and watch a full heating cycle. Flame dropping at the same point each time with a clean sensor points to gas supply or the valve. → Shop the flame sensor at Amazon
  5. Reset the lockout by removing power for more than 1 second only after the cause is fixed. If dropouts continue, call a pro to check gas pressure under load.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $150–$250

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) problems

See all Armstrong Air G2D93CT / G2D95CT (System Sentry control) codes & guides →