Armstrong Air G2D93CT / G2D95CT (System Sentry control) Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 9 problems covered.

Not sure of the code? Tap along with it

If your Armstrong Air Furnace blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
1 flashFlame present with the gas valve off. The control senses flame when no gas should be flowing.Gas valve leaking through or closing slowly›
2 flashesPressure switch closed with the inducer off. The control checks the switch before starting the inducer, and…Pressure switch contacts stuck closed›
3 flashesLow fire pressure switch, rollout switch, drain pressure switch, or auxiliary limit open. One of four…Low fire pressure switch did not close, from a blocked vent, a bad hose, or a weak›
4 flashesHigh limit switch open. The furnace overheated during a heating cycle, so the control shut off the gas valve…Dirty air filter or restricted airflow›
6 flashesPressure switch cycle lockout. The pressure switch opened and closed too many times during a call for heat…Pressure switch cycling open and closed during the run from marginal draft›
7 flashesLockout due to no ignition. The furnace tried to light and never proved flame, so the control locked out.No gas to the burners›
8 flashesLockout due to too many flame dropouts. Flame lit, then was lost too many times in one call for heat.Dirty flame sensor losing the signal›
9 flashesIncorrect polarity and phasing. The line voltage supply or the transformer phasing is reversed, so the…Line and neutral reversed at the furnace›
LED offNo power to the control, or the control has detected a hardware fault in itself.No power to the furnace or the control board›