Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) 2 flashes
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Pressure switch closed with the inducer off. The control checks the switch before starting the inducer, and it is already closed.
Likely causes
- Pressure switch contacts stuck closed
- Debris or water in the switch hose
- Short in the pressure switch wiring
How to fix it — step by step
- Turn the power off before opening the cabinet.
- Set the thermostat above room temperature later for the test, but first find the pressure switch. It sits near the inducer with a rubber hose and two wires.
- Pull the hose and check it is clear and dry, and clear the inducer port.
- With the inducer off, test the switch with a meter. Continuity with no draft means the switch is stuck closed.
- If the wiring is sound and the switch stays closed, replace the pressure switch with the correct setpoint part.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the pressure switch.
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.