Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) 6 flashes

What it should look like on your machine

then it repeats

6 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Pressure switch cycle lockout. The pressure switch opened and closed too many times during a call for heat, so the control locked out.

Likely causes

  1. Pressure switch cycling open and closed during the run from marginal draft
  2. Partially blocked vent or intake
  3. Weak inducer motor
  4. Failing pressure switch contacts

How to fix it — step by step

  1. Turn the power off before opening the cabinet.
  2. Check the vent and intake pipes end to end, including the outdoor terminations. A partial blockage gives draft that is almost enough, which cycles the switch.
  3. Pull the pressure switch hose and clear it and the inducer port.
  4. Restore power and call for heat. Listen to the inducer. A slow or noisy inducer points to the motor, not the switch. → Shop the inducer motor at Amazon
  5. Test the switch during a run with a meter. A switch that chatters open and closed under steady draft has failing contacts.
  6. Replace the pressure switch if draft is proven steady. Lockout clears by removing power for more than 1 second or removing the heat call for more than 3 seconds, per the manual, but fix the cause first.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $50–$215Typical pro repair $133–$505

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.