Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) 6 flashes
What it should look like on your machine
then it repeats
6 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Pressure switch cycle lockout. The pressure switch opened and closed too many times during a call for heat, so the control locked out.
Likely causes
- Pressure switch cycling open and closed during the run from marginal draft
- Partially blocked vent or intake
- Weak inducer motor
- Failing pressure switch contacts
How to fix it — step by step
- Turn the power off before opening the cabinet.
- Check the vent and intake pipes end to end, including the outdoor terminations. A partial blockage gives draft that is almost enough, which cycles the switch.
- Pull the pressure switch hose and clear it and the inducer port.
- Restore power and call for heat. Listen to the inducer. A slow or noisy inducer points to the motor, not the switch. → Shop the inducer motor at Amazon
- Test the switch during a run with a meter. A switch that chatters open and closed under steady draft has failing contacts.
- Replace the pressure switch if draft is proven steady. Lockout clears by removing power for more than 1 second or removing the heat call for more than 3 seconds, per the manual, but fix the cause first.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at Amazon
Also tied to this fault: inducer motor - Shop at Amazon
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- inducer motor$50–$215Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) problems
See all Armstrong Air G2D93CT / G2D95CT (System Sentry control) codes & guides →