Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) 3 flashes
What it should look like on your machine
then it repeats
3 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Low fire pressure switch, rollout switch, drain pressure switch, or auxiliary limit open. One of four switches on the safety chain has not proved, so the furnace will not start or will shut down.
Likely causes
- Low fire pressure switch did not close, from a blocked vent, a bad hose, or a weak inducer
- Rollout switch open
- Drain pressure switch open on a condensing model with a blocked drain
- Auxiliary limit switch open
How to fix it — step by step
- This one code covers four switches, so test them in order instead of replacing parts at random. Turn the power off first.
- Start with the low fire pressure switch by the inducer. Check its hose, clear the inducer port, and check the vent and intake terminations outside for blockage.
- Next check the condensate drain and trap on condensing models. A blocked drain opens the drain pressure switch and is a common cause.
- Find the rollout switch above the burners. If it is open, do not just reset it. Look for scorching and check the vent and inducer first, since rollout is a safety event.
- Test the auxiliary limit on the blower housing with a meter. Open when cold means it failed, or the blower area overheated.
- Restore power and call for heat while watching the sequence. The switch that keeps the sequence stopped is the one to repair or replace. Repeated rollout or limit trips need a pro.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at Amazon
Also tied to this fault: rollout switch - Shop at Amazon; auxiliary limit switch - Shop at Amazon
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- rollout switch$5–$35Shop at Amazon
- auxiliary limit switch$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Armstrong Air Furnace G2D93CT / G2D95CT (System Sentry control) problems
See all Armstrong Air G2D93CT / G2D95CT (System Sentry control) codes & guides →