Rheem Furnace Older LED blink-code control — Rheem/Ruud (Tech Tip TP0002; not modulating/two-stage/LXE) 2 blinks
What it should look like on your machine
then it repeats
2 blinks - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Pressure switch circuit open on older Rheem/Ruud furnaces with the blinking status LED board. Draft was not proven, commonly from venting or condensate problems in winter.
Likely causes
- blocked vent
- blocked pressure switch port → Shop the pressure switch at RepairClinic
- weak inducer motor → Shop the inducer motor at RepairClinic
- clogged condensate drain backing into the switch hose
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at RepairClinic or Amazon
Also tied to this fault: inducer motor - Shop at RepairClinic or Amazon
Parts that commonly fix it
- pressure switch - Shop at RepairClinic or Amazon
- inducer motor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.