Rheem Furnace Older LED blink-code control — Rheem/Ruud (Tech Tip TP0002; not modulating/two-stage/LXE) 1 blink

What it should look like on your machine

then it repeats

1 blink - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Soft lockout for one hour on older Rheem/Ruud furnaces with the blinking status LED board (per Rheem Tech Tip TP0002, not modulating/two-stage/LXE models). Four failed ignition tries or four flame losses in one call caused the lockout.

Likely causes

  1. failed ignition attempts
  2. flame loss during the cycle
  3. gas supply problem
  4. faulty igniter or dirty flame sensor → Shop the flame sensor at RepairClinic

How to fix it — step by step

  1. Check the thermostat is set to Heat and the furnace power switch and breaker are on
  2. Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
  3. Turn power off for 30 seconds, then back on, and allow one retry cycle
  4. Do not keep resetting a furnace that repeatedly fails to light
  5. If it locks out again, call a licensed HVAC technician and note the code

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Rheem Furnace Older LED blink-code control — Rheem/Ruud (Tech Tip TP0002; not modulating/two-stage/LXE) problems

See all Rheem Older LED blink-code control — Rheem/Ruud (Tech Tip TP0002; not modulating/two-stage/LXE) codes & guides →