A pressure washer that won't start splits first by power type, and both types share one precondition no other tool has: the water supply must be connected and the pump purged of air before starting, because running the pump without water severely damages its seals. On a gas model the engine branch is fuel, controls, oil and spark, plus one washer-only trap — trapped water pressure can stop the engine turning at all. On an electric model the branch is cord, breaker, GFCI and switch. Work your branch in order.
First checks: these apply to every brand
- Meet the water preconditions before you try to start it — SIMPSON's manual sets the supply the machine needs before starting: an uninterrupted source of clean, cold water at a minimum of 5 gallons per minute (GPM) at 20 PSI, with the inlet screen verified free of dirt and in place, and the supply hose run for 30 seconds to purge debris before it is threaded onto the pump inlet. Then purge the air from the pump and hoses as the manual's purging section directs: a pump is designed to operate with water flowing through it, and SIMPSON warns that running it without water will severely damage the pump seals and internal components, so the purge happens before the engine or motor is started, every time. A machine that has only ever been cranked dry may have a pump fault underneath its starting fault.
- Release trapped pressure if the cord barely pulls (gas) or the motor strains — SIMPSON lists this in its engine-will-not-start table: water pressure in the pump preventing the engine from rotating. The fix costs nothing: with the water supply on, aim the spray gun in a safe direction and pull the trigger to release the water pressure in the pump, then try the starter again. A recoil cord that pulled a few inches and stopped dead, or kicked back, and now pulls normally after the trigger was squeezed, was pressure-locked, not seized. Never aim the gun at anyone while doing this, and never touch a leak in a high-pressure hose or fitting — the manual's injection-injury warning is that this pressure can drive water through skin.
- Gas: set the engine controls and check the fuel — SIMPSON's engine-will-not-start table is a controls checklist before it is a parts list: fuel tank empty — add fresh fuel; engine switch in the OFF position — turn it ON; engine fuel valve turned OFF — turn it ON; choke in the wrong position — set it to the position the Starting Engine section specifies for a cold engine. Work all four before pulling again, because any one of them gives a complete no-start on a healthy engine. Fuel that has sat in the tank over a season is judged as in the other small-engine guides: drain and replace with fresh fuel rather than cranking stale fuel through the carburettor.
- Gas: check the oil — a low-oil sensor stops the start on purpose — SIMPSON's table states it directly: engine oil is low, and if the engine is equipped with a low oil sensor, the engine will not start. Check the level with the machine on a level surface and the engine off — unscrew the dipstick, wipe it, rest it in the filler neck without screwing it in, and read it; the level should reach the upper limit mark. The same manual's low-oil notice adds that the sensor stops the engine automatically when the level falls below the safe limit, and that the engine ships without oil, so a brand-new machine that has never been filled is this fault in its purest form. Fill with the oil the engine manual recommends, to the upper mark, and retest before suspecting the sensor itself.
- Gas: confirm the spark plug lead, then read the plug — The last item in SIMPSON's no-start table is the simplest: the spark plug lead is not attached to the plug — connect it, pushed fully onto the plug tip. If the lead is on and the engine still will not fire on proven fuel, oil and controls, remove the plug and read it as in the other two-stroke and small-engine guides: wet means flooded (choke drill and repeated pulls are the cause; clear it and restart on the run choke position), black and fouled means the plug is replaced, and a dry plug on an engine being cranked with the choke set points back at fuel delivery. Beyond the plug, SIMPSON refers engine troubleshooting to the engine owner's manual — carburettor and ignition diagnosis is engine-manual work, not washer-manual work.
- Electric: work the cord, breaker, GFCI and switch chain — SIMPSON's electric troubleshooting table lists the chain in order. Power supply cord not connected: plug it into a receptacle of the proper voltage and amperage — the manual specifies a dedicated 120 volt, 15 ampere receptacle. House circuit breaker tripped: reset it. GFCI tripped, whether the GFCI-equipped receptacle or the GFCI built into the power supply cord's plug (the manual provides GFCI protection in the cord plug and requires any replacement plug or cord to include it): press its RESET button. Master ON/OFF switch in the OFF position: move it to ON. Two load causes complete the table: other devices sharing the circuit — remove them — and an extension cord in the circuit — remove it and plug the washer's cord directly into the receptacle.
- Electric: if it stopped and won't restart, let the thermal switch cool it — An electric washer that ran, stopped, and now will not start at all may have tripped its own protection rather than failed: SIMPSON lists the thermal switch within the electric motor tripping due to overheating, with the correction to turn the master ON/OFF switch to OFF and allow the unit to cool for 30 minutes before trying again. A machine that starts after that cool-down was protected, not broken — but note what overheated it, because a motor repeatedly worked against a clogged nozzle, a starved water supply, or a shared, overloaded circuit will trip again. A machine that still will not start after cooling, with the whole cord-breaker-GFCI chain proven, has a motor or switch fault.
- If it starts but makes no pressure, change pages — Starting and pressurising are different faults on this machine. An engine or motor that now runs normally while the spray stays weak or absent has passed this page: the fault is in the water path — supply, inlet screen, nozzle, unloader or pump — and the pressure-washer-no-pressure guide works that branch in order. Do not keep working engine checks for a running engine.
Pressure washer won't start by brand
More house-power problems:
- Tripped breaker: find it and reset it
- GFCI outlet keeps tripping
- Outlet not working
- Half the house has no power
- Lights flickering
- Outlet sparking
- Power outage: the whole house is dark
The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:
- Furnace not turning on
- Washer won't start
- Dryer won't start
- Dishwasher won't start
- Hot tub won't turn on
- Reset an electric water heater
If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.
Parts that commonly fix it
- spark plugShop at Amazon
- spark plug leadShop at Amazon
- engine oilShop at Amazon
- water inlet screenShop at Amazon
- GFCI power cord$15–$85Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
When to call a pro: Call a pro or the manufacturer's service line if a gas engine still will not start after fuel, controls, oil and plug-lead checks (SIMPSON refers further engine diagnosis to the engine manual), if an electric model trips its breaker or GFCI again immediately with nothing else on the circuit, or if the pump was run dry and now leaks or makes no pressure. Never run a gas washer indoors or in a garage — carbon monoxide — and never bypass a GFCI or a low-oil sensor to make a machine start.