Power outage or blackout in a storm: the whole house is dark
When the whole house goes dark at once, the fault is almost never inside your walls. Either the utility supply has failed, or your main breaker or service connection has cut the whole house off in one go. There is very little to repair here, and that is the point of this guide: work out which side of the meter the problem sits on, make the house safe while you wait, check the panel once and properly, and know what the codes on your appliances mean when the power comes back. Work through the checks in order, with a flashlight, and stop at the one that matches what you can see. Storms cause most whole-house outages, and a grid blackout looks exactly the same from inside, so the same checks apply either way.
First checks: these apply to every brand
- First, work out whether it is the utility or just your house — Look outside before you touch anything. If the neighbours are dark and the streetlights are out, the whole street has lost supply and it is a utility outage: there is nothing in your house to reset, so report it and wait. Most utilities show reported outages on an outage map or app, and checking it takes a minute and tells you whether the fault is already known and roughly how wide it runs. If the street is lit and the neighbours have power but your house is completely dark, the problem is at your end of the supply: the main breaker has tripped, or the fault is at the service entrance where the supply cable meets your panel. That distinction decides everything that follows, because a utility outage is waited out, while a dark house on a lit street gets exactly one panel check, in check 3, and then a phone call. If only part of the house is dark, this is the wrong guide: one room or one run of outlets is a tripped breaker or GFCI, and roughly half the house with the big appliances dead is a lost leg. Both have their own guides.
- Make the house safe right now — Keep the refrigerator and freezer doors closed. A closed fridge holds a safe temperature for hours and a closed full freezer far longer, and every look inside trades that time away, so decide what you need before you open a door, and open it once. Switch off or unplug sensitive electronics and anything with a big motor, such as computers, TVs, the washer and the air conditioner: the risk is not the outage itself but the surge and the voltage swings that can arrive when supply is restored, and a house full of motors all trying to restart at the same moment does none of them any good. Leave one light switched on, ideally the one you will see first, so you know the moment power returns without watching the street. Use a flashlight rather than candles wherever you can; an unattended candle in a dark house is a fire risk at exactly the moment nobody can see it clearly. If you run a portable generator, it goes outside, never indoors and never in a garage, even with the garage door open: its exhaust carries carbon monoxide, an odourless gas that kills people in outages every year. Set it well away from the house with the exhaust pointing away from windows and doors, and let it cool before you refuel it.
- Check the panel once, properly — This check is only for the dark house on a lit street. Find the main breaker, the large switch at the top or bottom of the panel, and work with dry hands on a dry floor. A tripped main breaker sits partway between ON and OFF and will not reset from that middle position, so push it firmly all the way to OFF until it clicks, pause a moment, then push it firmly to ON. Stand to the side of the panel rather than directly in front of it and turn your face away as you flip, because if a fault is still present the breaker can arc as it closes. If the power comes back, you are done: go to check 4 for what to expect as the house restarts. If the main breaker trips again straight away, or it was never tripped and nothing changes, stop. Do not keep flipping it. The fault is at the service entrance or on the utility side of the meter, and neither is a homeowner reset. Open only the panel's hinged door, and never remove the screwed-on inner cover behind it: the conductors behind that cover stay live even with the main breaker off.
- When the power comes back: PF codes and the restart — Expect your appliances to have something to say about the outage. Many washers, dryers, ovens, dishwashers and microwaves display PF when power returns, and some GE microwaves show 888 or 8888 instead. PF stands for power failure, and it is the appliance reporting that its power was interrupted mid-cycle, not that a part has failed. The control stopped the cycle rather than guess its way through a restart, and it is holding the code until you acknowledge it. On most machines PF clears with a single button press, usually Cancel, Off or Clear, or by starting a fresh cycle; a refrigerator that shows PF, or PO for power outage on Whirlpool, Maytag and KitchenAid models, wants the same acknowledgement, and PO carries a second message, because it only appears when the freezer warmed up while the power was off, so check the food before you clear it and move on. Set the clocks, restart the cycles you still need, and give the fridge a few hours to pull its temperature back down with the doors kept closed. One caution covers the whole restart: power often comes back unevenly, with flickers and surges in the first minutes, so leave sensitive electronics unplugged until the lights have stayed steady for a while, and plug things back in gradually rather than all at once. If an appliance is still completely dead once the rest of the house is running normally, the outage is over and that appliance has its own fault: work through its own guide or its error code page from there. Surge damage, when it happens, usually announces itself: an appliance that is completely dead while everything around it works, electronics that restart themselves or behave oddly, a burnt smell or scorch mark at an outlet, or a breaker that trips the moment you reset it. Anything showing those signs stays unplugged until it has been checked, because a damaged power supply can overheat quietly. A plug-in surge protector guards the electronics you plug through it, and the parts list below carries one; a whole-house surge protector fitted at the panel guards the rest.
- Food safety in an outage: the 4-hour and 48-hour rules — The clock that matters most in a long outage is the one running on your food. Federal food-safety guidance from the FDA and USDA puts it in two numbers. A closed refrigerator keeps food safely cold for about 4 hours. A closed freezer holds its temperature for about 48 hours when it is full, and about 24 hours when it is half full, which is why the earlier check told you to keep the doors shut: every look inside spends part of that budget. Grouping food together in the freezer helps it stay cold longer, and if a storm is forecast, freezing containers of water ahead of time gives you ice that stretches the cold and later melts into drinking water. For an outage that runs past a day, dry ice or block ice buys real time: the FDA notes that 50 pounds of dry ice keeps an 18-cubic-foot full freezer cold for about two days. When the power returns, decide with a thermometer, not by smell: if a freezer thermometer reads 40 degrees F or below, the food is safe and can be refrozen, and food that still holds ice crystals or reads 40 degrees or below is safe to refreeze or cook. Refrigerated perishables are the strict case: meat, poultry, seafood, milk, eggs and leftovers that have spent 4 hours or more above 40 degrees get thrown out, and food that sat at room temperature for 2 hours or more (1 hour in heat above 90 degrees) goes too. You cannot judge any of this by appearance or odour, and tasting suspect food to test it is how people get sick. When in doubt, throw it out.
- Running a portable generator: what it can power, and the rules that keep it safe — A portable generator is a bridge for a short list of essentials, not a substitute for the grid. A typical mid-size portable, around 5,000 to 7,500 running watts, can carry a refrigerator or a freezer, the furnace blower so a gas or oil furnace makes heat, a few lights, phone chargers, and a medical device such as a CPAP. It cannot carry the whole house at once: central air conditioning, an electric range, an electric dryer and an electric water heater are each heavy loads, and stacking them on top of the essentials trips the generator or stalls it. Motors are the pinch point, because a fridge or blower motor draws a surge of power for a moment as it starts, so start the biggest load first and add the rest one at a time. Placement is the rule that saves lives, and it is not negotiable: the generator runs outside only, at least 20 feet from the house, with its exhaust pointed away from windows, doors and vents. Never run one in a garage, basement, carport or porch, even with the doors open: its exhaust is rich in carbon monoxide, a gas you cannot see or smell, and it kills people in outages every year. Battery-powered carbon monoxide alarms belong outside the sleeping areas and on every floor while a generator is in use, and the symptoms of CO poisoning (headache, dizziness, weakness, nausea, confusion) mean get outside first and call 911 from there. Connect appliances with heavy-duty outdoor extension cords, and never plug the generator into a wall outlet: that backfeeds power onto the utility lines and can kill a lineworker, so the only safe way to power house circuits is a transfer switch fitted by an electrician. For fuel, keep gasoline in an approved container stored away from the generator and from living spaces, let the engine cool before you refuel, and expect to refuel across a long outage rather than fill once and forget it. If anyone in the house depends on powered medical equipment, treat the generator as a bridge only: tell the utility before the next outage, and keep a battery backup charged.
- If you have a standby generator, it should already be running — A standby generator is automatic by design: it senses the loss of utility power and starts on its own within seconds, then a transfer switch moves the house onto generator power. If the house is dark and the generator never started, it has failed at the one job it exists for, and the branches are short. The starting battery is flat or failed, which is the most common cause, because a battery that is never asked to work still ages out. The controller has stopped it on a fault and is holding a fault code of its own, which the generator's display or its code pages carry in detail. It is out of fuel, or on natural gas models the supply is off. Or it has quietly failed its regular self-test exercise runs, which is how the first three causes usually announce themselves weeks earlier to anyone who checks. Do not improvise around a standby unit beyond reading its display: it is wired into your gas or fuel supply and your panel, and its repair is a generator technician's job. A portable generator is a different case with one absolute rule: never connect one to your house wiring without a transfer switch or an interlocked inlet fitted for the purpose. Plugging a portable generator into a household outlet backfeeds power out through the meter onto the street wiring, where it can kill a line worker who reasonably believes the line is dead. Run extension cords from a portable generator to individual appliances instead, and keep the generator itself outside, as check 2 sets out.
- Know who to call: utility, electrician, or 911 — Call the utility for anything that is clearly theirs: a street-wide or area outage, to report it and get a restoration estimate, and for partial power, where half the house is dead or the lights run bright and dim, reported as partial power or a possible lost leg. Utilities check their side of the meter at no charge, so they are the first call whenever the fault could sit on either side of it, including a single dark house on a lit street where the main breaker will not hold. Call a licensed electrician for faults that are plainly inside your installation: a panel that feels warm, a burning smell at the panel or an outlet, scorch marks or melted plastic, buzzing or crackling from the panel, or a main breaker that trips repeatedly once the utility has proved its side healthy. Call 911, from outside the house, for the emergencies: a downed power line, smoke, or flame. Treat every downed line as live, keep everyone and every pet well away from it, and never touch a line or anything in contact with one. If you smell burning and can switch the main breaker off safely with dry hands, do that while you wait, and if in doubt about which of the three a situation is, treat heat, smell and visible damage as the electrician-and-911 end of the scale, not the wait-and-see end.
If the outage is a storm or blackout
Most storm outages are the utility's to fix, not yours, but the hours around one have their own checks. Work through the main checks first to rule out a fault in your own house; then:
- Before the power comes back, unplug the sensitive things. When supply returns it can arrive with a surge. Unplug TVs, computers, game consoles and the appliance electronics you can reach, or switch them off at the outlet, and plug them back in a few minutes after the power is stable. Restarting one large appliance at a time is kinder to a recovering grid than everything starting at once.
- Keep the fridge and freezer shut. An unopened refrigerator keeps food at a safe temperature for about 4 hours; a full freezer holds for about 48 hours, a half-full one about 24. Every look inside spends cold you cannot replace, so decide what you need before you open the door.
- After the outage, judge food by the clock and the thermometer, not by smell. Per FDA and USDA guidance, refrigerated perishables (meat, poultry, seafood, milk, eggs, leftovers) that have been above 40 degrees F for 4 hours or more should be thrown out; frozen food that still holds ice crystals or reads 40 degrees or below can be refrozen. Food that smells fine can still be unsafe. When in doubt, throw it out.
- Treat every downed line as live. Stay well away, keep children and pets away, and never touch a line or anything in contact with one. Report it to the utility or call 911.
- When the power returns, walk the house once. Check for burning smells, buzzing outlets, and any appliance showing a code it has never shown before; the picker below hands you to the right guide for each one. Surge damage often shows up as an appliance that is simply dead, or one that trips its breaker repeatedly.
Power back on but an appliance is showing a code?
More house-power problems:
- Tripped breaker: find it and reset it
- GFCI outlet keeps tripping
- Outlet not working
- Half the house has no power
- Lights flickering
- Outlet sparking
The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:
- Furnace not turning on
- Washer won't start
- Dryer won't start
- Dishwasher won't start
- Hot tub won't turn on
- Reset an electric water heater
If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.
Running a portable generator during an outage
A portable generator will not run the whole house, and it is not meant to. Sized and placed correctly it comfortably covers the things that matter for a day or two:
- What it can run: the refrigerator and a freezer (the priority loads; they cycle, so they do not draw full power all the time), a furnace blower, lights, phones and laptops, a sump pump, and most medical devices. A typical 5,000 to 7,500 watt portable covers that list if you stagger the big loads rather than starting them together.
- What it cannot: central air conditioning, an electric range or dryer, and an electric water heater all at once. Run heavy appliances one at a time, or not at all.
- Placement is the safety rule that matters most: outside only, at least 20 feet from the house, with the exhaust pointed away from windows, doors and vents. Never in a garage, porch or basement, even with the door open: carbon monoxide from a generator can build up in minutes and has no smell. Battery CO alarms belong outside sleeping areas and on every floor while one is running.
- Fuel: let the engine cool before refuelling, store fuel in an approved container away from living spaces, and expect roughly 8 to 12 hours per tank at half load on a typical portable, so plan refuelling for daylight.
- Never backfeed: plug appliances into the generator's own outlets with heavy-duty extension cords, or use a transfer switch installed by an electrician. Feeding power into a wall outlet can energise the lines outside and kill a line worker.
Parts that commonly fix it
- flashlightShop at Amazon
- plug-in voltage testerShop at Amazon
- surge protectorShop at Amazon
When to call a pro: Call the utility first for an area outage, a single dark house on a lit street where the main breaker will not hold, and any partial power: they check their side of the meter at no charge. Call a licensed electrician if the panel feels warm, you smell burning at the panel or an outlet, you see scorch marks, melted plastic or sparking, or the main breaker trips repeatedly after the utility has cleared its side. Never run a portable generator indoors or connect one to house wiring without a transfer switch. If a line is down, or there is smoke or flame, get everyone out, keep well clear of the line, and call 911 from outside.