Half the house has no power

Half the house dark at once, with no single room to blame and the big appliances dead or half-working, is a different problem from a tripped breaker. Your home is fed by two 120-volt legs, and this pattern is what losing one of them looks like. There is very little to fix yourself here, and that is the point of this guide: recognise the pattern, protect your appliances, and call the right people in the right order, the utility first.

First checks: these apply to every brand

  1. Recognise the lost-leg pattern — Breakers alternate between the two legs as they run down the panel, so a lost leg kills roughly every other circuit, with dead outlets and lights scattered across several rooms, not one side of the house and not one room. The signature confirmation is the 240-volt appliances: an electric dryer that tumbles but does not heat, a range with dead burners, an air conditioner or electric water heater that will not run at all. One room or one run of outlets dead is a single circuit instead. That is the tripped-breaker guide's territory.
  2. Rule out the two simple explanations — First, look outside: if the neighbours are dark too, or your utility's outage map shows your area, it is a wider outage. Report it and wait. Second, check the main breaker (the large switch at the top or bottom of the panel) once: if it has tripped, reset it firmly OFF then ON. If it trips again, or nothing changes, stop resetting. The fault is at the service, not in a branch circuit.
  3. Turn off the big appliances while you wait — Motors and heating elements strain when fed by a single leg: switch off the air conditioner or heat pump, electric dryer, range and electric water heater at their controls or breakers until full power is back. This is also the moment to check for the urgent variant: if some lights are unusually BRIGHT while others are dim, and the brightness shifts as appliances switch on and off, the neutral connection is failing. The two legs drift out of balance and the voltage on one side can climb well above 120 volts. Unplug sensitive electronics and treat the call in the next check as urgent.
  4. Call the utility first: describe it as partial power — The fault can be on either side of the meter: the utility's transformer fuse, the service drop to your house or their connections, or on your side, in the meter base, the main breaker or the panel. Utilities check their side at no charge, so they are always the first call: report 'partial power' or a 'possible lost leg', and mention it if the lights are bright-and-dim. If the utility proves its side healthy, the fault is in your meter base or panel, and that is a licensed electrician's job.
  5. Know what is hands-off — Everything from the service drop to the panel's main lugs carries current that no switch in the house can turn off. The service conductors stay live even with the main breaker off. Never touch the meter, the wires entering the house, or anything inside the panel beyond flipping breaker handles, and never remove the panel's screwed-on inner cover. A downed or sagging line is live until the utility says otherwise: keep everyone, and pets, well away from it and call the utility or 911.

While you wait for the utility

More house-power problems:

The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:

If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.

Parts that commonly fix it

When to call a pro: This problem belongs to the utility and then, if their side is healthy, a licensed electrician. Call the same day: a failing service connection does not heal, and it can worsen. Call 911 instead if a line is down, or there is smoke, flame or a burning smell at the panel or meter; if you can do it safely and dry-handed, switch the main breaker off while you wait.