GFCI outlet keeps tripping

A GFCI that trips is doing the job it exists for: it has detected current leaking out of the circuit, possibly through water, a damaged cord or a failing appliance, and cut the power before that leak could run through a person. Resetting it is a homeowner job; the skill is in reading what the trip is telling you. Work through the checks in order: reset it properly, work out whether one appliance is causing it, and learn the signs that the GFCI itself has reached the end of its life.

First checks: these apply to every brand

  1. First, understand what a trip means — A GFCI compares the current leaving on the hot wire with the current returning on the neutral. If the two differ by more than about 5 milliamps, some current is taking another path to ground, through water, a damp appliance housing, or a person, and the GFCI cuts the power in a fraction of a second. That is why a trip is a report, not a nuisance: something on the circuit is leaking current, and the checks below find out whether it is an appliance, moisture, or the GFCI itself.
  2. Reset it properly, unplugged first — Unplug everything plugged into the GFCI and into any outlet it protects (the fifth check explains how to find those). With dry hands, press RESET firmly until it clicks and stays in. Then press TEST: the GFCI should trip with a click and cut the power. Press RESET again to restore it. A GFCI that trips on TEST and resets cleanly has just proved it can still protect you; one that will not trip on TEST, or trips and refuses to reset, has failed its own test. See the last check.
  3. If RESET will not stay in, read the lockout — Modern GFCIs refuse to reset for specific reasons. This is called reset lockout. Work through them in order: (1) No power reaching it: the breaker has tripped or a connection upstream has failed; a GFCI cannot reset with no supply, so check the panel. (2) The ground fault is still present: something still plugged in, or hard-wired on the circuit, is still leaking; unplug everything, including anything on the downstream outlets. (3) It was recently installed or replaced and the LINE and LOAD connections are reversed: a wiring error to correct with the power off, or an electrician's job. (4) The GFCI has failed its internal self-test: that is end of life, covered in the last check.
  4. Find the culprit by plugging back in, one at a time — With the GFCI reset and holding, plug the removed items back in one at a time and switch each on. The item that trips it is the fault: unplug it and leave it unplugged. The usual offenders are appliances that mix electricity with water or heat: kettles, coffee makers, hair dryers, pressure washers, sump and aquarium pumps, and older appliances whose insulation is breaking down. An appliance that trips any GFCI you plug it into has condemned itself: stop using it until it is serviced or replaced.
  5. Remember the downstream chain — One GFCI protects every ordinary outlet wired after it on the same circuit, its LOAD side, and that chain can cross rooms: a GFCI in a bathroom can be protecting outlets in the kitchen, the garage or outside. So the appliance causing the trip may not be plugged into the GFCI itself. When you do the plug-back-in test, include the plain-looking outlets in the wet areas the circuit serves. Use TEST to map the chain: press TEST on the GFCI and note every outlet that goes dead. Those are the ones it protects, and label them as GFCI protected.
  6. Trips only in wet weather point at water — If the GFCI behaves for weeks and then trips during or after rain, suspect moisture in an outdoor outlet box, a damp garage or basement appliance, or water in an extension lead or pond or aquarium equipment. Let everything dry, look for the box or device that got wet, and check outdoor outlets have in-use covers that close over a plugged-in cord. Repeated wet-weather trips with everything dry and unplugged mean the fault is in the wiring or a hard-wired device. That is the electrician line in the pro note below.
  7. When the GFCI itself is the failure — A GFCI with everything unplugged, on a circuit with proven power, that still trips the instant it is reset, or will not reset, clicks repeatedly, denies power, or shows a solid or flashing red status light on self-test models, has reached end of life. Those are the end-of-life signs: repeated trips on a reset attempt, clicking without delivering power, and an inability to reset. Test every GFCI monthly with its TEST and RESET buttons; one that fails the test is replaced like-for-like. Replacement is wiring work inside the box. Power off at the breaker and proven dead before anything is touched; if that is beyond you, it is a short electrician visit, and never an excuse to fit a plain outlet in its place: the protection is required exactly where GFCIs are installed.

Still tripping after the reset?

More house-power problems:

The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:

If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.

Parts that commonly fix it

When to call a pro: Call a licensed electrician if the GFCI trips instantly with everything unplugged and the circuit dry, because that is a ground fault in the wiring or a hard-wired device, if it trips again after a like-for-like replacement, or if you find any burning smell, scorch marks, heat or sparking at the outlet. If you see smoke or flame, get everyone out and call 911 from outside.