Outlet not working

One dead outlet with no tripped breaker looks like wiring trouble, but the cause is usually something simpler sitting between the panel and the outlet: a wall switch, a tripped GFCI in another room, or a breaker that does not look tripped. Work through the checks in order, as each one rules out a layer, and the last check names the one cause that really is in the wiring, and how it is found.

First checks: these apply to every brand

  1. Prove it is the outlet, not the appliance — Plug in something you know works, such as a lamp or a phone charger borrowed from another room. Try both sockets of the duplex: the two halves of an outlet can be wired separately, and one dead half with one live half is a clue, not a contradiction. It points at the switched-outlet check next.
  2. Flip every wall switch in the room — Many living rooms and bedrooms have a switched receptacle for a floor lamp, often only the top or bottom half (a 'half-hot' outlet), and sometimes the whole outlet. Leave the lamp plugged into the dead socket and work every switch in the room, including any that seem to do nothing. An outlet installed upside-down relative to the others in the room is a common tell that it is the switched one. If a switch brings it back, nothing was ever broken.
  3. Check the breaker, even if it looks fine — Panels are rarely labelled accurately, and a tripped breaker often rests only slightly off ON, easy to walk past. Run a fingertip down the row for the handle with a little give, and reset any suspect breaker properly: firmly OFF until it clicks, then ON. The full method, how to spot a tripped breaker and what an instant re-trip means, is in the tripped-breaker guide. If a breaker has tripped, something on the circuit tripped it; if it happens again, the GFCI guide's elimination test finds the appliance responsible.
  4. Hunt for the hidden GFCI — If the dead outlet is in or near a bathroom, kitchen, garage, basement, laundry room or outside wall, a tripped GFCI upstream is the most likely cause, and the GFCI is often not in the same room. One GFCI protects the plain outlets wired after it, so a bathroom outlet can be dead because of a GFCI in the garage, in another bathroom, or behind a garage refrigerator. Press RESET on every GFCI in the house. Protection can also live in the panel itself, as a GFCI breaker, a breaker with its own TEST button.
  5. Read the pattern: one outlet, or a run of them? — Outlets on a circuit are wired one after another from the panel. If a whole run is dead starting at one point while earlier outlets on the same circuit still work, a connection has opened at the last working outlet or the first dead one. Everything downstream of the break goes dark together. If only the one outlet is dead and its neighbours on the circuit work, the fault is at that outlet itself: a failed connection or a worn-out receptacle.
  6. The usual pinpoint: a loose or backstabbed connection — Most dead-outlet wiring faults are the push-in 'backstab' connections on the back of an outlet: the wire is held by a spring instead of a screw, and years of plugs being pushed in and pulled out work it loose until it lets go. Power stops, but nothing trips, because the wire has simply come off its termination. Finding it means opening the suspect outlets, the last working one and the first dead one, and moving the wires onto the side screw terminals, or replacing an outlet that shows heat damage. That is wiring work: breaker OFF, and the outlet proven dead with a tester before a screw is touched. If you are not confident doing that, this is the point to hand it to an electrician. Any outlet with scorch marks, melted plastic or a burning smell skips the DIY route entirely.

Still dead after the checks?

More house-power problems:

The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:

If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.

Parts that commonly fix it

When to call a pro: Call a licensed electrician if the breaker and every GFCI check out and the outlet (or the run) is still dead, because the fault is a connection inside a box, or sooner if the outlet is warm, discoloured or scorched, smells of burning, buzzes, or only works when the plug is wiggled: a loose connection that heats up gets worse, not better. Smoke or flame: get out and call 911.