Pressure washer has no pressure / low pressure
First split the symptom, because the two have different causes. No pressure at all — water comes out of the nozzle at roughly garden-hose force — usually means the water is bypassing the pump's pressure path: a detergent (soap) nozzle fitted, air still in the pump, or the unloader sending everything back to the inlet. Low pressure — a real jet, but weak — is usually starvation or wear: not enough water in, a clogged inlet screen or nozzle, or a worn nozzle, unloader or pump packing. Both branches work from the tap toward the pump, cheapest first.
First checks: these apply to every brand
- Prove the water supply: tap fully open, hose unkinked and big enough — Every manufacturer table read for this guide puts insufficient water supply first. Kärcher's troubleshooting for low operating pressure lists a closed faucet and a kinked inlet hose, corrected by opening the faucet and using a larger garden hose; SIMPSON quantifies the supply its machines need as at least 5 GPM at 20 PSI. So: tap fully open, walk the garden hose for kinks, crushed sections and leaks, and disconnect the hose and confirm it delivers a strong, full flow on its own before blaming the machine. A washer starved at the inlet cannot build pressure no matter how healthy its pump is, and fluctuating pressure with a surging jet is this same starvation showing intermittently.
- Clean the water inlet screen / strainer — Where the garden hose connects, the pump inlet carries a small screen or strainer that catches grit before it reaches the pump — and slowly chokes the supply when it clogs. Both Kärcher and SIMPSON list a clogged inlet screen/strainer as a low-or-no-pressure cause with the same correction: clean it per the maintenance section. Unscrew the hose, take the screen out, rinse it clean, and refit it (SIMPSON specifies the inlet screen sits with its convex side facing out). Pressure restored by a cleaned screen proves the diagnosis, and a screen that clogs again quickly points at debris in the supply hose or supply itself.
- Purge the air out of the pump and hoses — SIMPSON lists air in the hoses and/or pump as a cause of low or no spray pressure, corrected by priming/purging the pump as its manual directs, and Kärcher's fluctuating-pressure table gives the same physical test for a pump sucking air: check that all hoses and fittings are airtight, turn the machine off, and trigger the spray gun until a steady flow of water emerges through the nozzle. Air in the system gives a spitting, pulsing jet that never settles; a steady, air-free stream that is still weak moves you on to the nozzle. A fitting that leaks or draws air on the inlet side is fixed at the fitting — Kärcher's table notes re-taping plumbing leaks — not by running the machine harder.
- Check the nozzle: right type first, then clogged, then worn — Three nozzle faults, in order. Wrong nozzle: the black detergent (soap) nozzle is a low-pressure nozzle by design — SIMPSON's manual notes soaps will not draw unless it is fitted, and the corollary is that full pressure will not happen with it fitted, so confirm a high-pressure (coloured) nozzle is in the wand before diagnosing anything. Clogged: Kärcher lists an obstructed nozzle under fluctuating pressure, corrected by blowing it out or removing debris with a fine needle, and SIMPSON lists a clogged nozzle under low or no pressure, cleaned per its maintenance section — a partially blocked nozzle also overloads the engine, per Kärcher's table. Worn: a nozzle that has enlarged with use passes more water at less pressure, and both manufacturers list it under 'pressure low after a period of normal use' with the same verdict — replace the nozzle, matched to the machine.
- Check for leaks and pressure loss on the high-pressure side — Pressure made by the pump but lost before the nozzle looks exactly like pressure never made. Kärcher's low-pressure table includes plumbing and hose leaks, corrected by checking the system for leaks and re-taping them. Work the high-pressure hose, the gun and the lance connections under pressure (visually only — never run a hand over a pressurised hose or fitting feeling for a leak, and never touch a leak in a high-pressure line: the injection-injury risk in the manuals is explicit). A hose or fitting that sprays, weeps or bubbles is replaced or resealed, and pressure retested, before the pump itself is suspected.
- Judge the unloader valve: the bypass that can swallow all the pressure — The unloader valve diverts water back to the pump inlet when the trigger is released, and it is the part that can quietly take the whole output with it. Kärcher lists a faulty or mis-adjusted unloader valve under low operating pressure — adjust it for proper pressure, install a repair kit when needed, call the local distributor — and a worn unloader valve under pressure low after a period of normal use, with the verdict: replace the unloader valve. The pattern that points here is specific: full, steady water flow with the trigger pulled but little pressure behind it, with supply, screen, air and nozzle all proven — the pump is moving water that is bypassing instead of pressurising. Note Kärcher's caution from its other manual: tampering with the factory unloader setting can cause injury and voids the warranty, so adjustment beyond your own manual's procedure is dealer work.
- Last branch: pump valves and packing — the wear inside the pump — If supply, screen, air, nozzle, leaks and unloader are all proven, the loss is inside the pump. Kärcher's tables name the parts: worn packing in the pump (dealer/customer support), fouled or dirty inlet or discharge valves (clean them), and worn inlet or discharge valves (replace with a valve kit); fluctuating pressure with worn or dirty pump valves is the same family. Two history clues support this branch: a machine stored in freezing temperatures, which Kärcher lists with the correction to thaw the machine completely, including hose, gun and wand, before judging anything; and slow engine RPM on a gas model, which starves the pump of speed rather than water. Internal pump work — packing kits, valve kits, bearings — is where the manufacturers' own tables hand the machine to a dealer.
Pressure washer no pressure by brand
More house-power problems:
- Tripped breaker: find it and reset it
- GFCI outlet keeps tripping
- Outlet not working
- Half the house has no power
- Lights flickering
- Outlet sparking
- Power outage: the whole house is dark
The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:
- Furnace not turning on
- Washer won't start
- Dryer won't start
- Dishwasher won't start
- Hot tub won't turn on
- Reset an electric water heater
If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.
Parts that commonly fix it
- spray nozzleShop at Amazon
- water inlet screenShop at Amazon
- unloader valveShop at Amazon
- pump packing kitShop at Amazon
- pump valve kitShop at Amazon
- high-pressure hoseShop at Amazon
When to call a pro: Call a dealer or service centre for anything inside the pump — packing, valves, bearings — for a worn unloader valve that needs replacement, and for any machine that still has no pressure with supply, screen, nozzle and unloader proven. Never adjust an unloader past the procedure in your own manual (Kärcher warns the factory setting is a safety and warranty line), and get immediate medical attention for any high-pressure injection injury, however small the mark looks.