A leaf blower that won't start is failing on a different supply depending on how it is powered, so split by power type first. Gas models need fuel mix, air and spark, and most of their no-starts are stale mix, a primer bulb that is not moving fuel, the wrong choke setting, or a fouled plug. Cordless models need a charged, fully seated battery pack. Corded models need a live outlet and an undamaged cord. Work the branch that matches your machine, in order.
First checks: these apply to every brand
- Split by power type, and set the controls before blaming parts — Decide which machine you have and check its free controls first. On a gas blower, confirm there is fuel mix in the tank, the stop switch or setting lever moves easily to the run position, and the spark plug boot is pushed firmly onto the plug — STIHL's manual warns a loose boot can spark and is a fire risk, and lists a switch left at STOP as a starting check in its own right. On a cordless blower, confirm the pack is pushed in until it latches. On a corded blower, confirm the switch is OFF before plugging in, then that the plug is fully in the outlet. A control left in the wrong position imitates a failed part on all three types.
- Gas: judge the fuel mix — age and ratio before anything else — Two-stroke blowers run on gasoline mixed with two-stroke oil, never straight gasoline. STIHL's manual for the BG 56/66/86 family specifies a 1:50 gasoline-to-STIHL two-stroke oil mix and states plainly that fuel mixture deteriorates with age: mix only as much as needed for a few weeks and do not store the mixture for longer than 30 days. Fuel older than that, or left in the machine over a season, is the prime suspect: drain the tank and refill with fresh, correctly mixed fuel rather than topping old mix up. The wrong mix also fouls the plug — STIHL lists too much oil in the fuel mix as a cause of plug fouling — so a blower that has been run on a suspect mix gets fresh fuel and a plug check together.
- Gas: press the primer (manual fuel pump) bulb and watch it — On models with a manual fuel pump, STIHL's starting procedure is to press the bulb at least five times, even if the bulb is already filled with fuel, and to press it at least five times again after a tank that was run completely dry has been refuelled. A healthy bulb fills with fuel and springs back. A bulb that stays flat, feels cracked or stiff, or pumps only air is not delivering fuel to the carburettor: the bulb itself, the fuel lines, or the fuel pickup body (filter) in the tank is the fault. STIHL schedules the fuel pickup body for replacement every year and lists the in-tank filter as a check item, so a bulb that will not prime on fresh fuel points at that hidden end of the fuel system, not at the engine.
- Gas: use the choke for the engine's temperature, not by habit — STIHL's drill separates cold from warm. If the engine is cold, turn the choke knob to the closed (cold-start) position; if the engine is warm, or has been running but is still cold, use the run/start position instead. Place the machine on level ground, hold it firmly, pull the starter grip slowly until it engages and then give it a brisk pull, without pulling the rope all the way out. As soon as the engine runs, blip the throttle trigger: on these models the choke knob moves to the run position and the engine returns to idle. If the engine stops in the choke position or during acceleration, move the choke to the run position and keep cranking until it runs. Repeated pulling on full choke floods the engine, which is the next check.
- Gas: flooded engine — stop priming and clear it — A strong smell of raw fuel after many pulls, especially with the choke closed or the bulb pressed repeatedly, means the cylinder holds more fuel than it can burn. Stop priming and stop choking it. The clearing pattern in the Husqvarna chainsaw manual for the same two-stroke fault is the model procedure: remove and clean or dry the spark plug, turn the machine so the plug hole points away from you, pull the starter rope 6 to 8 times to clear the combustion chamber, refit the plug, and restart with the choke in the run position. A plug that comes out wet confirms the flood; a plug that comes out dry sends you back to the fuel-delivery check above.
- Gas: check the air filter and the spark plug — STIHL states that dirty air filters reduce engine power, increase fuel consumption and make starting more difficult, so take the filter out before condemning anything deeper: knock a flat or pleated element out on your palm or blow it clear, wash a pleated filter only as the manual directs, and replace a damaged or clogged element. Then the plug: STIHL's instruction is to check the spark plug first whenever the engine is difficult to start, down on power, or runs poorly at idle. Pull the boot, unscrew the plug, clean it, and check the electrode gap against the Specifications section of your own manual — gaps differ by model, so do not borrow a number from another machine. Rectify what fouled it (too much oil in the mix, a dirty air filter, unfavourable running conditions are STIHL's listed causes) and fit a new approved plug if the electrodes are badly eroded.
- Cordless: read the battery pack's own charge indicator, then reseat the pack — On a cordless blower the lights that matter are the battery pack's own charge indicator, not a fault code on the tool. On EGO 56V packs, the pack's 5-LED indicator shows charge level in green (5 LEDs shining green is 80 to 100 percent, down to 1 LED shining green at 10 to 20 percent); 1 LED flashing red means the charge is under 10 percent, 5 LEDs flashing red means the pack is nearly depleted and needs charging immediately, and 5 LEDs shining red is the pack's over-temperature signal — cool the pack until its temperature drops below 152°F (67°C), as the battery manual directs. Those are battery signals from the pack and charger manuals, and other brands use different patterns, so read yours against its own battery manual. Then the mechanical check EGO and Toro both list for a tool that does not start: remove the pack and refit it until it is fully installed and latched, because a pack that is not fully seated is a named cause, alongside a pack that is not charged and a damaged pack, which is replaced.
- Corded: prove the outlet, then judge the cord and switch — A corded blower has no fuel or battery branch: prove the supply instead. Try a known-live outlet, reset any tripped GFCI protecting that outlet, and inspect the cord and plug along their whole length. Toro's corded blower/vac manual is explicit: do not use the appliance with a damaged electrical cord or plug — a machine with a damaged cord, or one that is not working as it should, goes to a service dealer rather than being taped up and run. If the outlet is live, the cord and plug are undamaged, and the motor still will not run with the inlet cover locked in place (Toro notes the motor should not run unless that cover is locked in, and a motor that runs without it is also a dealer return), the fault is inside the motor or switch, which is where owner checks on a corded machine end.
Leaf blower won't start by brand
More house-power problems:
- Tripped breaker: find it and reset it
- GFCI outlet keeps tripping
- Outlet not working
- Half the house has no power
- Lights flickering
- Outlet sparking
- Power outage: the whole house is dark
The checks above cover the house's side of the problem. If the power is back but one appliance is still dead, or one appliance keeps tripping the breaker, the fault is in the appliance, and its own guide takes over:
- Furnace not turning on
- Washer won't start
- Dryer won't start
- Dishwasher won't start
- Hot tub won't turn on
- Reset an electric water heater
If the whole house is dark and you have a standby generator that should have started on its own and did not, that is a generator fault, not a panel fault: start with Generator won't start, or go straight to generator codes and problems by brand.
Parts that commonly fix it
- spark plugShop at Amazon
- air filterShop at Amazon
- primer bulbShop at Amazon
- fuel pickup body (fuel filter)Shop at Amazon
- fuel lineShop at Amazon
- battery packShop at Amazon
When to call a pro: Take it to a servicing dealer if a gas blower still will not start on fresh, correctly mixed fuel with a priming bulb, a clean filter and a good plug, which points to the carburettor or ignition; if there is any fuel leak — STIHL is explicit: do not start the engine, fire risk, have the machine serviced first; or if a corded blower has a damaged cord or plug. Never run a gas blower indoors: the exhaust is toxic even when you cannot smell it.