Navien NCB-H series Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 27 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E001 | E001 is a heat exchanger over temperature fault and needs a manual reset. The water in the heat exchanger got… | Heat exchanger over temperature | › |
| E003 | E003 is ignition failure and needs a manual reset. The boiler tried to light the burner and did not establish… | Ignition failure | › |
| E004 | E004 is false flame detection. The boiler is reporting a flame signal when there should not be one, and… | False flame detection | › |
| E012 | E012 is flame loss and needs a manual reset. The burner lit and then the flame was lost during operation. The… | Flame loss during operation | › |
| E016 | E016 is overheating of the heat exchanger and needs a manual reset. The listed remedy starts with time: turn… | Overheating of heat exchanger | › |
| E030 | E030 is abnormal exhaust temperature and needs a manual reset. The exhaust leaving the boiler is hotter than… | Abnormal exhaust temperature | › |
| E031 | E031 is overheating of the burner and needs a manual reset. The burner itself ran too hot, which is a… | Overheating of burner | › |
| E046 | E046 is abnormal operation of the limit control and resets automatically when the condition clears. The limit… | Abnormal operation: limit control | › |
| E047 | E047 is abnormal operation of the exhaust thermostat. The thermostat that watches exhaust temperature is… | Abnormal operation: exhaust thermostat | › |
| E060 | E060 is abnormal operation of the dual venturi. The dual venturi is part of the gas and air mixing system… | Abnormal operation: dual venturi | › |
| E109 | E109 is abnormal operation of the fan motor and needs a manual reset. The fan proves combustion air movement… | Abnormal operation: fan motor | › |
| E110 | E110 is abnormal air pressure and needs a manual reset. In the NCB-H user's manual table this code covers the… | Abnormal air pressure | › |
| E205 | E205 is a heating supply thermistor open or short circuit and resets automatically when the fault clears. The… | Heating supply thermistor open circuit | › |
| E218 | E218 is a heating return thermistor open or short circuit, shown as an alarm. The boiler has lost its heating… | Heating return thermistor open circuit | › |
| E351 | E351 is abnormal operation of the auto feeder valve, the make-up water valve, and needs a manual reset. On… | Abnormal auto feeder valve (make-up water) | › |
| E352 | E352 is high water pressure and resets automatically when pressure falls back into range. The heating system… | High water pressure in the heating system | › |
| E353 | E353 is abnormal operation of the water pressure sensor and resets automatically when a valid reading… | Abnormal operation: water pressure sensor | › |
| E407 | E407 is a domestic hot water thermistor open or short circuit and resets automatically when the fault clears.… | Domestic hot water thermistor open circuit | › |
| E439 | E439 is abnormal operation of the flow sensor, shown as an alarm. The flow sensor tells the boiler when… | Abnormal operation: flow sensor | › |
| E515 | E515 is abnormal operation of the PCB and needs a manual reset. The listed checks are grounding and reset… | Abnormal operation: PCB | › |
| E517 | E517 is abnormal operation of the DIP switch setting on the PCB and needs a manual reset. The board's DIP… | Abnormal operation: DIP switch setting | › |
| E594 | E594 is abnormal operation of the EEPROM, shown as an alarm. The EEPROM holds the boiler's stored settings… | Abnormal operation: EEPROM | › |
| E615 | E615 is abnormal operation of input and memory. The control's input processing and memory are reporting… | Abnormal operation: input and memory | › |
| E736 | E736 is abnormal operation of cascade communication, shown as an alarm. On a cascaded bank of Navien boilers… | Abnormal operation: cascade communication | › |
| E740 | E740 is abnormal operation of the outdoor temperature sensor, and it appears only when the outdoor reset… | Outdoor temperature sensor not detected | › |
| E777 | E777 is the low water cutoff activated. The low water cutoff has shut the boiler down because it is not… | Low water cutoff activated | › |
| E788 | E788 is an incorrect gas type setting. The gas type set on the circuit board DIP switch does not match the… | Incorrect gas type setting | › |