What the E736 code means

E736 is abnormal operation of cascade communication, shown as an alarm. On a cascaded bank of Navien boilers the units talk to each other, and E736 means that communication has failed. A single boiler that is not part of a cascade should not be set up as one, which is part of the check.

Likely causes

  1. Abnormal operation: cascade communication
  2. Cascade communication cable fault
  3. Cascade settings fault

How to fix it — step by step

  1. Record the code before resetting: write down E736 exactly as shown on the NCB-H front panel display, and note whether heating, hot water, or both were running.
  2. Safety: if you smell gas, do not touch electrical switches, leave and call the gas supplier from outside. Otherwise turn the boiler off and close its manual gas shut-off valve before any cover comes off, and keep gas, burner and vent work to a qualified installer.
  3. Locate the parts: the cascade communication connections are on the boilers' PCBs, linked by the cascade cable between units, and E736 is read on the front panel display of the unit reporting it.
  4. Test: check the cascade cable connections at each unit and confirm the cascade settings match the number of boilers actually installed. Sound cabling and correct settings with E736 returning point to a communication input on one unit's PCB, which a technician isolates by substitution.
  5. End at the fix: reseat or replace the cascade cable, or correct the cascade settings, and the alarm clears. A returning E736 on proven cabling is a technician PCB level repair.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E736 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Navien Boiler NCB-H series error codes

See all Navien NCB-H series codes & guides →