Navien Boiler NCB-H series E060 Error Code

What the E060 code means

E060 is abnormal operation of the dual venturi. The dual venturi is part of the gas and air mixing system, and abnormal operation means the boiler cannot trust its combustion mixture control. This is a sealed combustion system fault with no owner remedy listed.

Likely causes

  1. Abnormal operation: dual venturi
  2. Dual venturi fault

How to fix it — step by step

  1. Record the code before resetting: write down E060 exactly as shown on the NCB-H front panel display, and note whether heating, hot water, or both were running.
  2. Safety: if you smell gas, do not touch electrical switches, leave and call the gas supplier from outside. Otherwise turn the boiler off and close its manual gas shut-off valve before any cover comes off, and keep gas, burner and vent work to a qualified installer.
  3. Locate the parts: the dual venturi sits in the gas and air path between the fan, gas valve and burner inside the NCB-H cabinet, and E060 is read on the front panel display.
  4. Test: keep the gas train closed. A technician proves gas supply and fan operation first; both sound with E060 returning pinpoints the dual venturi assembly itself.
  5. End at the pinpoint: E060 pinpoints the dual venturi in the gas and air path, and a qualified installer replaces or repairs it. Do not run the boiler on repeated resets.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E060 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Navien Boiler NCB-H series error codes

See all Navien NCB-H series codes & guides →