Navien Boiler NCB-H series E740 Error Code
What the E740 code means
E740 is abnormal operation of the outdoor temperature sensor, and it appears only when the outdoor reset curve is enabled. The listed check is the outdoor reset curve setting and the sensor wiring. Without a valid outdoor reading the boiler cannot run its reset curve, but the sensor circuit is a low voltage check an installer can prove quickly.
Likely causes
- Outdoor temperature sensor not detected
- Outdoor sensor wiring fault
- Outdoor reset curve enabled with no sensor fitted
How to fix it — step by step
- Record the code before resetting: write down E740 exactly as shown on the NCB-H front panel display, and note whether heating, hot water, or both were running.
- Safety: if you smell gas, do not touch electrical switches, leave and call the gas supplier from outside. Otherwise turn the boiler off and close its manual gas shut-off valve before any cover comes off, and keep gas, burner and vent work to a qualified installer.
- Locate the parts: the outdoor temperature sensor is mounted outside the building and wired back to the boiler PCB; E740 is read on the front panel display.
- Test: check whether an outdoor sensor is actually fitted, then check its wiring back to the boiler. A fitted sensor that measures correctly at the boiler terminals clears the circuit and points to settings; no sensor fitted with the reset curve enabled explains the code by itself.
- End at the fix: repair the sensor wiring, replace a faulty outdoor sensor, or correct the reset curve setting if no sensor is used. The alarm clears when a valid outdoor reading returns.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor temperature sensor.
Parts that commonly fix the E740 code
- Outdoor temperature sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.