What the E016 code means

E016 is overheating of the heat exchanger and needs a manual reset. The listed remedy starts with time: turn the boiler off for at least 30 minutes, then restart it, and the heat exchanger may need flushing. Repeated E016 means the exchanger is not shedding heat or is scaled enough to overheat.

Likely causes

  1. Overheating of heat exchanger
  2. Restricted heating water flow
  3. Scaled heat exchanger needing a flush

How to fix it — step by step

  1. Record the code before resetting: write down E016 exactly as shown on the NCB-H front panel display, and note whether heating, hot water, or both were running.
  2. Safety: if you smell gas, do not touch electrical switches, leave and call the gas supplier from outside. Otherwise turn the boiler off and close its manual gas shut-off valve before any cover comes off, and keep gas, burner and vent work to a qualified installer.
  3. Locate the parts: the heat exchanger fills most of the NCB-H cabinet, the heating return filter is in the return waterway at the bottom of the boiler, and E016 is read on the front panel display.
  4. Test: after the 30 minute cool down, restart and watch how fast the supply temperature climbs on a heating call. A fast climb with a cool return proves poor flow; normal flow with repeat overheating points to scale inside the heat exchanger, which a flush tests and treats.
  5. End at the fix: restore flow or have the heat exchanger flushed, then reset. If E016 returns after a flush with flow proven, a technician inspects the exchanger and its sensors.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E016 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Navien Boiler NCB-H series error codes

See all Navien NCB-H series codes & guides →