Lennox Furnace SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series DS1 slow flash, DS2 on

What this problem usually means

On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 slow flash with DS2 on means a primary, secondary or rollout limit is open. If a limit stays open 3 minutes the furnace enters a one-hour Watchguard.

Likely causes

  1. Dirty air filter overheating the furnace
  2. Closed registers or blocked returns
  3. Tripped rollout switch
  4. Failed limit switch → Shop the limit switch at RepairClinic

How to fix it — step by step

  1. Turn the thermostat down and let the furnace cool
  2. Replace the air filter and open all registers
  3. Do not reset a rollout switch yourself → Shop the rollout switch at RepairClinic
  4. Call for heat once after cooling; if the pattern returns, call a technician

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.